PVC Orange Circular 4C+E (450/750V & 0.6/1kV)
PVC Orange Circular 4C+E (450/750V & 0.6/1kV)
4 core+earth, circular, V-90 insulated, PVC sheathed to AS/NZS 5000, Copper conductors, 90°C. Manufactured to PVC Best Practice.
Read more1.5mm 4C&E O/C 0.6/1KV
Nexans ref. HNHP05AA004OMAA - Country ref. HNHP05AA004OMAA
- Packaging: Cut to length (m)
- Type of conductor: Stranded copper
- Conductor cross-section: 1.5 mm²
- Earth conductor cross section: 1.5 mm²
- Rated Voltage Uo/U (Um): 0,6/1 kV
- Maximum Pull Tension of Conductor: 0 kN
- Maximum Pulling Tension: 1.4 kN
- Minimum Bend Radius - During Installation (under Tension): 71 mm
- Minimum Bend Radius - Installed: 48 mm
1.5mm 4C&E O/C 0.6/1KV 500m
Nexans ref. HNHP05A5004OMAA - Country ref. HNHP05A5004OMAA
- Type of conductor: Stranded copper
- Conductor cross-section: 1.5 mm²
- Earth conductor cross section: 1.5 mm²
- Rated Voltage Uo/U (Um): 0,6/1 kV
- Maximum Pull Tension of Conductor: 0 kN
- Maximum Pulling Tension: 1.4 kN
- Minimum Bend Radius - During Installation (under Tension): 70 mm
- Minimum Bend Radius - Installed: 48 mm
1.5mm 4C&E O/C 450/750V 100m
Nexans ref. GNHP05A1004OMAA - Country ref. GNHP05A1004OMAA
- Type of conductor: Stranded copper
- Conductor cross-section: 1.5 mm²
- Earth conductor cross section: 1.5 mm²
- Rated Voltage Uo/U (Um): 450/750 V
- Maximum Pull Tension of Conductor: 0 kN
- Maximum Pulling Tension: 1.2 kN
- Minimum Bend Radius - During Installation (under Tension): 60 mm
- Minimum Bend Radius - Installed: 40 mm
1.5mm 4C&E O/C 450/750V 500m
Nexans ref. GNHP05A5004OMAA - Country ref. GNHP05A5004OMAA
- Type of conductor: Stranded copper
- Conductor cross-section: 1.5 mm²
- Earth conductor cross section: 1.5 mm²
- Rated Voltage Uo/U (Um): 450/750 V
- Maximum Pull Tension of Conductor: 0 kN
- Maximum Pulling Tension: 1.2 kN
- Minimum Bend Radius - During Installation (under Tension): 60 mm
- Minimum Bend Radius - Installed: 40 mm
10mm 4C&E O/C 0.6/1KV
Nexans ref. HNHP13AA004OMAA - Country ref. HNHP13AA004OMAA
- Packaging: Cut to length (m)
- Type of conductor: Stranded copper
- Conductor cross-section: 10 mm²
- Earth conductor cross section: 4 mm²
- Rated Voltage Uo/U (Um): 0,6/1 kV
- Maximum Pull Tension of Conductor: 3 kN
- Maximum Pulling Tension: 2.3 kN
- Minimum Bend Radius - During Installation (under Tension): 120 mm
- Minimum Bend Radius - Installed: 77 mm
10mm 4C&E O/C 0.6/1KV 100m
Nexans ref. HNHP13A1004OMAA - Country ref. HNHP13A1004OMAA
- Type of conductor: Stranded copper
- Conductor cross-section: 10 mm²
- Earth conductor cross section: 4 mm²
- Rated Voltage Uo/U (Um): 0,6/1 kV
- Maximum Pull Tension of Conductor: 3 kN
- Maximum Pulling Tension: 2.3 kN
- Minimum Bend Radius - During Installation (under Tension): 120 mm
- Minimum Bend Radius - Installed: 77 mm
10mm 4C&E O/C 0.6/1KV 500m
Nexans ref. HNHP13A5004OMAA - Country ref. HNHP13A5004OMAA
- Type of conductor: Stranded copper
- Conductor cross-section: 10 mm²
- Earth conductor cross section: 4 mm²
- Rated Voltage Uo/U (Um): 0,6/1 kV
- Maximum Pull Tension of Conductor: 3 kN
- Maximum Pulling Tension: 2.3 kN
- Minimum Bend Radius - During Installation (under Tension): 120 mm
- Minimum Bend Radius - Installed: 77 mm
120mm 4C&E O/C 0.6/1KV
Nexans ref. HNHP23AA004OMAA - Country ref. HNHP23AA004OMAA
- Packaging: Cut to length (m)
- Type of conductor: Compact copper
- Conductor cross-section: 120 mm²
- Earth conductor cross section: 35 mm²
- Rated Voltage Uo/U (Um): 0,6/1 kV
- Maximum Pull Tension of Conductor: 25 kN
- Maximum Pulling Tension: 5.7 kN
- Minimum Bend Radius - During Installation (under Tension): 290 mm
- Minimum Bend Radius - Installed: 190 mm
16mm 4C&E O/C 0.6/1KV
Nexans ref. HNHP15AA004OMAA - Country ref. HNHP15AA004OMAA
- Packaging: Cut to length (m)
- Type of conductor: Stranded copper
- Conductor cross-section: 16 mm²
- Earth conductor cross section: 6 mm²
- Rated Voltage Uo/U (Um): 0,6/1 kV
- Maximum Pull Tension of Conductor: 4 kN
- Maximum Pulling Tension: 2.6 kN
- Minimum Bend Radius - During Installation (under Tension): 130 mm
- Minimum Bend Radius - Installed: 86 mm
16mm 4C&E O/C 0.6/1KV 100m
Nexans ref. HNHP15A1004OMAA - Country ref. HNHP15A1004OMAA
- Type of conductor: Stranded copper
- Conductor cross-section: 16 mm²
- Earth conductor cross section: 6 mm²
- Rated Voltage Uo/U (Um): 0,6/1 kV
- Maximum Pull Tension of Conductor: 4 kN
- Maximum Pulling Tension: 2.6 kN
- Minimum Bend Radius - During Installation (under Tension): 130 mm
- Minimum Bend Radius - Installed: 86 mm
16mm 4C&E O/C 0.6/1KV 500m
Nexans ref. HNHP15A5004OMAA - Country ref. HNHP15A5004OMAA
- Type of conductor: Stranded copper
- Conductor cross-section: 16 mm²
- Earth conductor cross section: 6 mm²
- Rated Voltage Uo/U (Um): 0,6/1 kV
- Maximum Pull Tension of Conductor: 4 kN
- Maximum Pulling Tension: 2.6 kN
- Minimum Bend Radius - During Installation (under Tension): 130 mm
- Minimum Bend Radius - Installed: 86 mm
2.5mm 4C&E O/C (450/750V)
Nexans ref. GNHP07AA004OMAA - Country ref. GNHP07AA004OMAA
- Packaging: Cut to length (m)
- Type of conductor: Stranded copper
- Conductor cross-section: 2.5 mm²
- Earth conductor cross section: 2.5 mm²
- Rated Voltage Uo/U (Um): 450/750 V
- Maximum Pull Tension of Conductor: 1 kN
- Maximum Pulling Tension: 1.4 kN
- Minimum Bend Radius - During Installation (under Tension): 72 mm
- Minimum Bend Radius - Installed: 48 mm
2.5mm 4C&E O/C (450/750V) 500m
Nexans ref. GNHP07A5004OMAA - Country ref. GNHP07A5004OMAA
- Type of conductor: Stranded copper
- Conductor cross-section: 2.5 mm²
- Earth conductor cross section: 2.5 mm²
- Rated Voltage Uo/U (Um): 450/750 V
- Maximum Pull Tension of Conductor: 1 kN
- Maximum Pulling Tension: 1.4 kN
- Minimum Bend Radius - During Installation (under Tension): 72 mm
- Minimum Bend Radius - Installed: 48 mm
2.5mm 4C&E O/C (450/750v) 100m
Nexans ref. GNHP07A1004OMAA - Country ref. GNHP07A1004OMAA
- Type of conductor: Stranded copper
- Conductor cross-section: 2.5 mm²
- Earth conductor cross section: 2.5 mm²
- Rated Voltage Uo/U (Um): 450/750 V
- Maximum Pull Tension of Conductor: 1 kN
- Maximum Pulling Tension: 1.4 kN
- Minimum Bend Radius - During Installation (under Tension): 72 mm
- Minimum Bend Radius - Installed: 48 mm
2.5mm 4C&E O/C 0.6/1KV
Nexans ref. HNHP07AA004OMAA - Country ref. HNHP07AA004OMAA
- Packaging: Cut to length (m)
- Type of conductor: Stranded copper
- Conductor cross-section: 2.5 mm²
- Earth conductor cross section: 2.5 mm²
- Rated Voltage Uo/U (Um): 0,6/1 kV
- Maximum Pull Tension of Conductor: 1 kN
- Maximum Pulling Tension: 1.6 kN
- Minimum Bend Radius - During Installation (under Tension): 80 mm
- Minimum Bend Radius - Installed: 53 mm
2.5mm 4C&E O/C 0.6/1KV 500m
Nexans ref. HNHP07A5004OMAA - Country ref. HNHP07A5004OMAA
- Type of conductor: Stranded copper
- Conductor cross-section: 2.5 mm²
- Earth conductor cross section: 2.5 mm²
- Rated Voltage Uo/U (Um): 0,6/1 kV
- Maximum Pull Tension of Conductor: 1 kN
- Maximum Pulling Tension: 1.6 kN
- Minimum Bend Radius - During Installation (under Tension): 80 mm
- Minimum Bend Radius - Installed: 53 mm
25mm 4C&E O/C 0.6/1KV
Nexans ref. HNHC17AA004OMAA - Country ref. HNHC17AA004OMAA
- Packaging: Cut to length (m)
- Type of conductor: Stranded copper
- Conductor cross-section: 25 mm²
- Earth conductor cross section: 6 mm²
- Rated Voltage Uo/U (Um): 0,6/1 kV
- Maximum Pull Tension of Conductor: 7 kN
- Maximum Pulling Tension: 2.9 kN
- Minimum Bend Radius - During Installation (under Tension): 290 mm
- Minimum Bend Radius - Installed: 200 mm
35mm 4C&E O/C 0.6/1KV
Nexans ref. HNHC18AA004OMAA - Country ref. HNHC18AA004OMAA
- Packaging: Cut to length (m)
- Type of conductor: Compact copper
- Conductor cross-section: 35 mm²
- Earth conductor cross section: 10 mm²
- Rated Voltage Uo/U (Um): 0,6/1 kV
- Maximum Pull Tension of Conductor: 10 kN
- Maximum Pulling Tension: 3.3 kN
- Minimum Bend Radius - During Installation (under Tension): 330 mm
- Minimum Bend Radius - Installed: 220 mm
4mm 4C&E O/C 0.6/1KV
Nexans ref. HNHP09AA004OMAA - Country ref. HNHP09AA004OMAA
- Packaging: Cut to length (m)
- Type of conductor: Stranded copper
- Conductor cross-section: 4 mm²
- Earth conductor cross section: 2.5 mm²
- Rated Voltage Uo/U (Um): 0,6/1 kV
- Maximum Pull Tension of Conductor: 1 kN
- Maximum Pulling Tension: 1.8 kN
- Minimum Bend Radius - During Installation (under Tension): 92 mm
- Minimum Bend Radius - Installed: 61 mm
4mm 4C&E O/C 0.6/1KV 500m
Nexans ref. HNHP09A5004OMAA - Country ref. HNHP09A5004OMAA
- Type of conductor: Stranded copper
- Conductor cross-section: 4 mm²
- Earth conductor cross section: 2.5 mm²
- Rated Voltage Uo/U (Um): 0,6/1 kV
- Maximum Pull Tension of Conductor: 1 kN
- Maximum Pulling Tension: 1.8 kN
- Minimum Bend Radius - During Installation (under Tension): 92 mm
- Minimum Bend Radius - Installed: 61 mm
4mm 4C&E O/C 450/750V
Nexans ref. GNHP09AA004OMAA - Country ref. GNHP09AA004OMAA
- Packaging: Cut to length (m)
- Type of conductor: Stranded copper
- Conductor cross-section: 4 mm²
- Earth conductor cross section: 2.5 mm²
- Rated Voltage Uo/U (Um): 450/750 V
- Maximum Pull Tension of Conductor: 1 kN
- Maximum Pulling Tension: 1.7 kN
- Minimum Bend Radius - During Installation (under Tension): 83 mm
- Minimum Bend Radius - Installed: 55 mm
4mm 4C&E O/C 450/750V 100m
Nexans ref. GNHP09A1004OMAA - Country ref. GNHP09A1004OMAA
- Type of conductor: Stranded copper
- Conductor cross-section: 4 mm²
- Earth conductor cross section: 2.5 mm²
- Rated Voltage Uo/U (Um): 450/750 V
- Maximum Pull Tension of Conductor: 1 kN
- Maximum Pulling Tension: 1.7 kN
- Minimum Bend Radius - During Installation (under Tension): 83 mm
- Minimum Bend Radius - Installed: 55 mm
4mm 4C&E O/C 450/750V 500m
Nexans ref. GNHP09A5004OMAA - Country ref. GNHP09A5004OMAA
- Type of conductor: Stranded copper
- Conductor cross-section: 4 mm²
- Earth conductor cross section: 2.5 mm²
- Rated Voltage Uo/U (Um): 450/750 V
- Maximum Pull Tension of Conductor: 1 kN
- Maximum Pulling Tension: 1.7 kN
- Minimum Bend Radius - During Installation (under Tension): 83 mm
- Minimum Bend Radius - Installed: 55 mm
6mm 4C&E O/C 0.6/1KV
Nexans ref. HNHP11AA004OMAA - Country ref. HNHP11AA004OMAA
- Packaging: Cut to length (m)
- Type of conductor: Stranded copper
- Conductor cross-section: 6 mm²
- Earth conductor cross section: 2.5 mm²
- Rated Voltage Uo/U (Um): 0,6/1 kV
- Maximum Pull Tension of Conductor: 2 kN
- Maximum Pulling Tension: 2 kN
- Minimum Bend Radius - During Installation (under Tension): 99 mm
- Minimum Bend Radius - Installed: 66 mm
6mm 4C&E O/C 0.6/1KV 500m
Nexans ref. HNHP11A5004OMAA - Country ref. HNHP11A5004OMAA
- Type of conductor: Stranded copper
- Conductor cross-section: 6 mm²
- Earth conductor cross section: 2.5 mm²
- Rated Voltage Uo/U (Um): 0,6/1 kV
- Maximum Pull Tension of Conductor: 2 kN
- Maximum Pulling Tension: 2 kN
- Minimum Bend Radius - During Installation (under Tension): 99 mm
- Minimum Bend Radius - Installed: 66 mm
6mm 4C&E O/C 450/750V
Nexans ref. GNHP11AA004OMAA - Country ref. GNHP11AA004OMAA
- Packaging: Cut to length (m)
- Type of conductor: Stranded copper
- Conductor cross-section: 6 mm²
- Earth conductor cross section: 2.5 mm²
- Rated Voltage Uo/U (Um): 450/750 V
- Maximum Pull Tension of Conductor: 2 kN
- Maximum Pulling Tension: 1.8 kN
- Minimum Bend Radius - During Installation (under Tension): 90 mm
- Minimum Bend Radius - Installed: 60 mm
6mm 4C&E O/C 450/750V 100m
Nexans ref. GNHP11A1004OMAA - Country ref. GNHP11A1004OMAA
- Type of conductor: Stranded copper
- Conductor cross-section: 6 mm²
- Earth conductor cross section: 2.5 mm²
- Rated Voltage Uo/U (Um): 450/750 V
- Maximum Pull Tension of Conductor: 2 kN
- Maximum Pulling Tension: 1.8 kN
- Minimum Bend Radius - During Installation (under Tension): 90 mm
- Minimum Bend Radius - Installed: 60 mm
6mm 4C&E O/C 450/750V 500m
Nexans ref. GNHP11A5004OMAA - Country ref. GNHP11A5004OMAA
- Type of conductor: Stranded copper
- Conductor cross-section: 6 mm²
- Earth conductor cross section: 2.5 mm²
- Rated Voltage Uo/U (Um): 450/750 V
- Maximum Pull Tension of Conductor: 2 kN
- Maximum Pulling Tension: 1.8 kN
- Minimum Bend Radius - During Installation (under Tension): 90 mm
- Minimum Bend Radius - Installed: 60 mm
70mm 4C&E O/C 0.6/1KV
Nexans ref. HNHC20AA004OMAA - Country ref. HNHC20AA004OMAA
- Packaging: Cut to length (m)
- Type of conductor: Compact copper
- Conductor cross-section: 70 mm²
- Earth conductor cross section: 25 mm²
- Rated Voltage Uo/U (Um): 0,6/1 kV
- Maximum Pull Tension of Conductor: 20 kN
- Maximum Pulling Tension: 4.3 kN
- Minimum Bend Radius - During Installation (under Tension): 430 mm
- Minimum Bend Radius - Installed: 290 mm
95mm 4C&E O/C 0.6/1KV
Nexans ref. HNHC22AA004OMAA - Country ref. HNHC22AA004OMAA
- Packaging: Cut to length (m)
- Type of conductor: Compact copper
- Conductor cross-section: 95 mm²
- Earth conductor cross section: 25 mm²
- Rated Voltage Uo/U (Um): 0,6/1 kV
- Maximum Pull Tension of Conductor: 25 kN
- Maximum Pulling Tension: 5 kN
- Minimum Bend Radius - During Installation (under Tension): 500 mm
- Minimum Bend Radius - Installed: 340 mm
Description
Description
Standards
-
ProductAS/NZS 1125; AS/NZS 5000.1; AS/NZS 5000.2
- 4 core+earth, circular,
- V-90 insulated,
- 90°C PVC sheathed to AS/NZS 5000,
- Copper conductors.
- GNHP 450/750V to AS/NZS 5000.2
- HNHP 0.6/1kV to AS/NZS 5000.1
Note: Earth cores smaller than 25mm² are not compacted.
* Due to a change in standard AS/NZS 5000.2, the minimum calculated value of the sheath thickness for circular multicore cables has reduced, therefore also reducing the OD and mass for 1.5mm2–6mm2 cables.
Orange Circular; Circs
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Mechanical characteristics
Mechanical characteristics
Resources
Resources
PVC Circular 3C + 4C and Earth - Current carrying capacities three phase (in Amps)
Copper Conductor
Insulation PVC
Maximum Conductor Temperature 75⁰C
Conductor cross-section |
|
|
|
|
|
|
|
|
|
---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
1.0 | 13.0 | 12.0 | 9.0 | 6.0 | 11.0 | 9.0 | 5.0 | 19.0 | 14.0 |
1.5 | 16.0 | 15.0 | 12.0 | 8.0 | 14.0 | 11.0 | 7.0 | 24.0 | 18.0 |
2.5 | 23.0 | 22.0 | 17.0 | 11.0 | 20.0 | 16.0 | 10.0 | 34.0 | 25.0 |
4.0 | 31.0 | 29.0 | 23.0 | 15.0 | 25.0 | 20.0 | 13.0 | 44.0 | 33.0 |
6.0 | 40.0 | 37.0 | 30.0 | 19.0 | 33.0 | 26.0 | 16.0 | 55.0 | 42.0 |
10.0 | 54.0 | 51.0 | 41.0 | 25.0 | 44.0 | 35.0 | 22.0 | 74.0 | 55.0 |
16.0 | 72.0 | 68.0 | 54.0 | 34.0 | 58.0 | 47.0 | 29.0 | 96.0 | 73.0 |
25.0 | 97.0 | 91.0 | 73.0 | 46.0 | 76.0 | 60.0 | 38.0 | 125.0 | 94.0 |
35.0 | 120.0 | 112.0 | 90.0 | 56.0 | 94.0 | 75.0 | 47.0 | 150.0 | 114.0 |
50.0 | 146.0 | 137.0 | 109.0 | 0.0 | 112.0 | 89.0 | 0.0 | 178.0 | 136.0 |
70.0 | 185.0 | 172.0 | 138.0 | 0.0 | 142.0 | 114.0 | 0.0 | 219.0 | 170.0 |
95.0 | 228.0 | 213.0 | 170.0 | 0.0 | 177.0 | 142.0 | 0.0 | 263.0 | 208.0 |
120.0 | 265.0 | 247.0 | 198.0 | 0.0 | 202.0 | 162.0 | 0.0 | 300.0 | 237.0 |
150.0 | 303.0 | 282.0 | 226.0 | 0.0 | 228.0 | 182.0 | 0.0 | 336.0 | 266.0 |
185.0 | 348.0 | 324.0 | 259.0 | 0.0 | 263.0 | 211.0 | 0.0 | 379.0 | 304.0 |
240.0 | 412.0 | 383.0 | 307.0 | 0.0 | 316.0 | 253.0 | 0.0 | 438.0 | 359.0 |
300.0 | 472.0 | 438.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 493.0 | 404.0 |
400.0 | 544.0 | 504.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 557.0 | 468.0 |
500.0 | 616.0 | 571.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 620.0 | 522.0 |
Unenclosed spaced |
Unenclosed touching |
Unenclosed and partially surrounded by thermal insulation |
Unenclosed and completely surrounded by thermal insulation |
Enclosed conduit in air |
Enclosed, partially surrounded by thermal insulation |
Enclosed, completely surrounded by thermal insulation |
Buried direct |
Underground ducts |