PVC Insulated Single Core
PVC Insulated Single Core
Single core, 0.6/1kV V-90 insulated, to AS/NZS 5000.1 (unsheathed), copper conductors, 90°C. Manufactured to PVC Best Practice Guidelines.
Read more1.5mm2 PVC Building Wire Black 100m
Nexans ref. BAAP05A1001AABK - Country ref. BAAP05A1001AABK
- Colour: Black
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 1.5 mm²
- Maximum Pulling Tension: 0.11 kN
- Minimum Bend Radius - During Installation (under Tension): 19 mm
- Minimum Bend Radius - Installed: 12 mm
1.5mm2 PVC Building Wire Black 500m
Nexans ref. BAAP05A5001AABK - Country ref. BAAP05A5001AABK
- Colour: Black
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 1.5 mm²
- Maximum Pulling Tension: 0.11 kN
- Minimum Bend Radius - During Installation (under Tension): 19 mm
- Minimum Bend Radius - Installed: 12 mm
1.5mm2 PVC Building Wire Blue 100m
Nexans ref. BAAP05A1001AABE - Country ref. BAAP05A1001AABE
- Colour: Blue
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 1.5 mm²
- Maximum Pulling Tension: 0.11 kN
- Minimum Bend Radius - During Installation (under Tension): 19 mm
- Minimum Bend Radius - Installed: 12 mm
1.5mm2 PVC Building Wire Green/Yellow 100m
Nexans ref. AATP05A1001AAHN - Country ref. AATP05A1001AAHN
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 1.5 mm²
- Maximum Pulling Tension: 0.11 kN
- Minimum Bend Radius - During Installation (under Tension): 20 mm
- Minimum Bend Radius - Installed: 14 mm
1.5mm2 PVC Building Wire Grey 100m
Nexans ref. BAAP05A1001AAGY - Country ref. BAAP05A1001AAGY
- Colour: Grey
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 1.5 mm²
- Maximum Pulling Tension: 0.11 kN
- Minimum Bend Radius - During Installation (under Tension): 19 mm
- Minimum Bend Radius - Installed: 12 mm
1.5mm2 PVC Building Wire Red 100m
Nexans ref. BAAP05A1001AARD - Country ref. BAAP05A1001AARD
- Colour: Red
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 1.5 mm²
- Maximum Pulling Tension: 0.11 kN
- Minimum Bend Radius - During Installation (under Tension): 19 mm
- Minimum Bend Radius - Installed: 12 mm
1.5mm2 PVC Building Wire Red 500m
Nexans ref. BAAP05A5001AARD - Country ref. BAAP05A5001AARD
- Colour: Red
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 1.5 mm²
- Maximum Pulling Tension: 0.11 kN
- Minimum Bend Radius - During Installation (under Tension): 19 mm
- Minimum Bend Radius - Installed: 12 mm
1.5mm2 PVC Building Wire White 100m
Nexans ref. BAAP05A1001AAWT - Country ref. BAAP05A1001AAWT
- Colour: White
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 1.5 mm²
- Maximum Pulling Tension: 0.11 kN
- Minimum Bend Radius - During Installation (under Tension): 19 mm
- Minimum Bend Radius - Installed: 12 mm
1.5mm2 PVC Building Wire White 500m
Nexans ref. BAAP05A5001AAWT - Country ref. BAAP05A5001AAWT
- Colour: White
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 1.5 mm²
- Maximum Pulling Tension: 0.11 kN
- Minimum Bend Radius - During Installation (under Tension): 19 mm
- Minimum Bend Radius - Installed: 12 mm
10mm2 PVC Building Wire Black 100m
Nexans ref. BAAP13A1001AABK - Country ref. BAAP13A1001AABK
- Colour: Black
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 10 mm²
- Maximum Pulling Tension: 0.7 kN
- Minimum Bend Radius - During Installation (under Tension): 36 mm
- Minimum Bend Radius - Installed: 24 mm
10mm2 PVC Building Wire Black 500m
Nexans ref. BAAP13A5001AABK - Country ref. BAAP13A5001AABK
- Colour: Black
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 10 mm²
- Maximum Pulling Tension: 0.7 kN
- Minimum Bend Radius - During Installation (under Tension): 36 mm
- Minimum Bend Radius - Installed: 24 mm
10mm2 PVC Building Wire Blue 100m
Nexans ref. BAAP13A1001AABE - Country ref. BAAP13A1001AABE
- Colour: Blue
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 10 mm²
- Maximum Pulling Tension: 0.7 kN
- Minimum Bend Radius - During Installation (under Tension): 36 mm
- Minimum Bend Radius - Installed: 24 mm
10mm2 PVC Building Wire Green/Yellow
Nexans ref. BAAP13AA001AAHN - Country ref. BAAP13AA001AAHN
- Packaging: Cut to length (m)
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: - m
- Conductor cross-section: 16 mm²
- Maximum Pulling Tension: 1.1 kN
- Minimum Bend Radius - During Installation (under Tension): 36 mm
- Minimum Bend Radius - Installed: 24 mm
10mm2 PVC Building Wire Green/Yellow 100m
Nexans ref. BAAP13A1001AAHN - Country ref. BAAP13A1001AAHN
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 10 mm²
- Maximum Pulling Tension: 0.7 kN
- Minimum Bend Radius - During Installation (under Tension): 36 mm
- Minimum Bend Radius - Installed: 24 mm
10mm2 PVC Building Wire Green/Yellow 500m
Nexans ref. BAAP13A5001AAHN - Country ref. BAAP13A5001AAHN
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 10 mm²
- Maximum Pulling Tension: 0.7 kN
- Minimum Bend Radius - During Installation (under Tension): 36 mm
- Minimum Bend Radius - Installed: 24 mm
10mm2 PVC Building Wire Red 100m
Nexans ref. BAAP13A1001AARD - Country ref. BAAP13A1001AARD
- Colour: Red
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 10 mm²
- Maximum Pulling Tension: 0.7 kN
- Minimum Bend Radius - During Installation (under Tension): 36 mm
- Minimum Bend Radius - Installed: 24 mm
10mm2 PVC Building Wire Red 500m
Nexans ref. BAAP13A5001AARD - Country ref. BAAP13A5001AARD
- Colour: Red
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 10 mm²
- Maximum Pulling Tension: 0.7 kN
- Minimum Bend Radius - During Installation (under Tension): 36 mm
- Minimum Bend Radius - Installed: 24 mm
10mm2 PVC Building Wire White 100m
Nexans ref. BAAP13A1001AAWT - Country ref. BAAP13A1001AAWT
- Colour: White
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 10 mm²
- Maximum Pulling Tension: 0.7 kN
- Minimum Bend Radius - During Installation (under Tension): 36 mm
- Minimum Bend Radius - Installed: 24 mm
120mm2 PVC Building Wire Black
Nexans ref. BAAP23AA001AABK - Country ref. BAAP23AA001AABK
- Packaging: Cut to length (m)
- Colour: Black
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: - m
- Conductor cross-section: 120 mm²
- Maximum Pulling Tension: 8.4 kN
- Minimum Bend Radius - During Installation (under Tension): 98 mm
- Minimum Bend Radius - Installed: 66 mm
120mm2 PVC Building Wire Green/Yellow
Nexans ref. BAAP23AA001AAHN - Country ref. BAAP23AA001AAHN
- Packaging: Cut to length (m)
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: - m
- Conductor cross-section: 120 mm²
- Maximum Pulling Tension: 8.4 kN
- Minimum Bend Radius - During Installation (under Tension): 98 mm
- Minimum Bend Radius - Installed: 66 mm
120mm2 PVC Building Wire Green/Yellow (100m pack)
Nexans ref. BAAP23A1001AAHN - Country ref. BAAP23A1001AAHN
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 120 mm²
- Maximum Pulling Tension: 8.4 kN
- Minimum Bend Radius - During Installation (under Tension): 98 mm
- Minimum Bend Radius - Installed: 66 mm
120mm2 PVC Building Wire Green/Yellow 500m
Nexans ref. BAAP23A5001AAHN - Country ref. BAAP23A5001AAHN
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 120 mm²
- Maximum Pulling Tension: 8.4 kN
- Minimum Bend Radius - During Installation (under Tension): 98 mm
- Minimum Bend Radius - Installed: 66 mm
150mm2 PVC Building Wire Black
Nexans ref. BAAP24AA001AABK - Country ref. BAAP24AA001AABK
- Packaging: Cut to length (m)
- Colour: Black
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: - m
- Conductor cross-section: 150 mm²
- Maximum Pulling Tension: 11 kN
- Minimum Bend Radius - During Installation (under Tension): 110 mm
- Minimum Bend Radius - Installed: 75 mm
150mm2 PVC Building Wire Green/Yellow
Nexans ref. BAAP24AA001AAHN - Country ref. BAAP24AA001AAHN
- Packaging: Cut to length (m)
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: - m
- Conductor cross-section: 150 mm²
- Maximum Pulling Tension: 11 kN
- Minimum Bend Radius - During Installation (under Tension): 110 mm
- Minimum Bend Radius - Installed: 75 mm
16mm2 PVC Building Wire Black 500m
Nexans ref. BAAP15A5001AABK - Country ref. BAAP15A5001AABK
- Colour: Black
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 16 mm²
- Maximum Pulling Tension: 1.1 kN
- Minimum Bend Radius - During Installation (under Tension): 41 mm
- Minimum Bend Radius - Installed: 28 mm
16mm2 PVC Building Wire Blue 100m
Nexans ref. BAAP15A1001AABE - Country ref. BAAP15A1001AABE
- Colour: Blue
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 16 mm²
- Maximum Pulling Tension: 1.1 kN
- Minimum Bend Radius - During Installation (under Tension): 41 mm
- Minimum Bend Radius - Installed: 28 mm
16mm2 PVC Building Wire Blue 500m
Nexans ref. BAAP15A5001AABE - Country ref. BAAP15A5001AABE
- Colour: Blue
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 16 mm²
- Maximum Pulling Tension: 1.1 kN
- Minimum Bend Radius - During Installation (under Tension): 41 mm
- Minimum Bend Radius - Installed: 28 mm
16mm2 PVC Building Wire Green/Yellow
Nexans ref. BAAP15AA001AAHN - Country ref. BAAP15AA001AAHN
- Packaging: Cut to length (m)
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: - m
- Conductor cross-section: 16 mm²
- Maximum Pulling Tension: 1.1 kN
- Minimum Bend Radius - During Installation (under Tension): 41 mm
- Minimum Bend Radius - Installed: 28 mm
16mm2 PVC Building Wire Green/Yellow 100m
Nexans ref. BAAP15A1001AAHN - Country ref. BAAP15A1001AAHN
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 16 mm²
- Maximum Pulling Tension: 1.1 kN
- Minimum Bend Radius - During Installation (under Tension): 41 mm
- Minimum Bend Radius - Installed: 28 mm
16mm2 PVC Building Wire Green/Yellow 500m
Nexans ref. BAAP15A5001AAHN - Country ref. BAAP15A5001AAHN
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 16 mm²
- Maximum Pulling Tension: 1.1 kN
- Minimum Bend Radius - During Installation (under Tension): 41 mm
- Minimum Bend Radius - Installed: 28 mm
16mm2 PVC Building Wire Red 100m
Nexans ref. BAAP15A1001AARD - Country ref. BAAP15A1001AARD
- Colour: Red
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 16 mm²
- Maximum Pulling Tension: 1.1 kN
- Minimum Bend Radius - During Installation (under Tension): 41 mm
- Minimum Bend Radius - Installed: 28 mm
16mm2 PVC Building Wire Red 500m
Nexans ref. BAAP15A5001AARD - Country ref. BAAP15A5001AARD
- Colour: Red
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 16 mm²
- Maximum Pulling Tension: 1.1 kN
- Minimum Bend Radius - During Installation (under Tension): 41 mm
- Minimum Bend Radius - Installed: 28 mm
16mm2 PVC Building Wire White 100m
Nexans ref. BAAP15A1001AAWT - Country ref. BAAP15A1001AAWT
- Colour: White
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 16 mm²
- Maximum Pulling Tension: 1.1 kN
- Minimum Bend Radius - During Installation (under Tension): 41 mm
- Minimum Bend Radius - Installed: 28 mm
16mm2 PVC Building Wire White 500m
Nexans ref. BAAP15A5001AAWT - Country ref. BAAP15A5001AAWT
- Colour: White
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 16 mm²
- Maximum Pulling Tension: 1.1 kN
- Minimum Bend Radius - During Installation (under Tension): 41 mm
- Minimum Bend Radius - Installed: 28 mm
185mm2 PVC Building Wire Green/Yellow
Nexans ref. BAAP25AA001AAHN - Country ref. BAAP25AA001AAHN
- Packaging: Cut to length (m)
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: - m
- Conductor cross-section: 185 mm²
- Maximum Pulling Tension: 13 kN
- Minimum Bend Radius - During Installation (under Tension): 250 mm
- Minimum Bend Radius - Installed: 160 mm
1mm2 PVC Building Wire Black 100m
Nexans ref. BAAP02A1001AABK - Country ref. BAAP02A1001AABK
- Colour: Black
- Conductor flexibility: Solid class 1
- Type of conductor: Solid copper
- Cable length: 100 m
- Conductor cross-section: 1 mm²
- Maximum Pulling Tension: 0.07 kN
- Minimum Bend Radius - During Installation (under Tension): 34 mm
- Minimum Bend Radius - Installed: 22 mm
1mm2 PVC Building Wire Red 100m
Nexans ref. BAAP02A1001AARD - Country ref. BAAP02A1001AARD
- Colour: Red
- Conductor flexibility: Solid class 1
- Type of conductor: Solid copper
- Cable length: 100 m
- Conductor cross-section: 1 mm²
- Maximum Pulling Tension: 0.07 kN
- Minimum Bend Radius - During Installation (under Tension): 34 mm
- Minimum Bend Radius - Installed: 22 mm
1mm2 PVC Building Wire White 100m
Nexans ref. BAAP02A1001AAWT - Country ref. BAAP02A1001AAWT
- Colour: White
- Conductor flexibility: Solid class 1
- Type of conductor: Solid copper
- Cable length: 100 m
- Conductor cross-section: 1 mm²
- Maximum Pulling Tension: 0.07 kN
- Minimum Bend Radius - During Installation (under Tension): 34 mm
- Minimum Bend Radius - Installed: 22 mm
1mm2 PVC Building Wire White 500m
Nexans ref. BAAP02A5001AAWT - Country ref. BAAP02A5001AAWT
- Colour: White
- Conductor flexibility: Solid class 1
- Type of conductor: Solid copper
- Cable length: 500 m
- Conductor cross-section: 1 mm²
- Maximum Pulling Tension: 0.07 kN
- Minimum Bend Radius - During Installation (under Tension): 34 mm
- Minimum Bend Radius - Installed: 22 mm
2.5mm2 PVC Building Wire Black 500m
Nexans ref. BAAP07A1001AABK - Country ref. BAAP07A1001AABK
- Colour: Black
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 2.5 mm²
- Maximum Pulling Tension: 0.18 kN
- Minimum Bend Radius - During Installation (under Tension): 22 mm
- Minimum Bend Radius - Installed: 14 mm
2.5mm2 PVC Building Wire Black 500m
Nexans ref. BAAP07A5001AABK - Country ref. BAAP07A5001AABK
- Colour: Black
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 2.5 mm²
- Maximum Pulling Tension: 0.18 kN
- Minimum Bend Radius - During Installation (under Tension): 22 mm
- Minimum Bend Radius - Installed: 14 mm
2.5mm2 PVC Building Wire Blue 100m
Nexans ref. BAAP07A1001AABE - Country ref. BAAP07A1001AABE
- Colour: Blue
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 2.5 mm²
- Maximum Pulling Tension: 0.18 kN
- Minimum Bend Radius - During Installation (under Tension): 22 mm
- Minimum Bend Radius - Installed: 14 mm
2.5mm2 PVC Building Wire Blue 500m
Nexans ref. BAAP07A5001AABE - Country ref. BAAP07A5001AABE
- Colour: Blue
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 2.5 mm²
- Maximum Pulling Tension: 0.18 kN
- Minimum Bend Radius - During Installation (under Tension): 22 mm
- Minimum Bend Radius - Installed: 14 mm
2.5mm2 PVC Building Wire Green/Yellow 100m
Nexans ref. AATP07A1001AAHN - Country ref. AATP07A1001AAHN
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 2.5 mm²
- Maximum Pulling Tension: 0.18 kN
- Minimum Bend Radius - During Installation (under Tension): 16 mm
- Minimum Bend Radius - Installed: 11 mm
2.5mm2 PVC Building Wire Green/Yellow 500m
Nexans ref. AATP07A5001AAHN - Country ref. AATP07A5001AAHN
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 2.5 mm²
- Maximum Pulling Tension: 0.18 kN
- Minimum Bend Radius - During Installation (under Tension): 20 mm
- Minimum Bend Radius - Installed: 14 mm
2.5mm2 PVC Building Wire Grey 100m
Nexans ref. BAAP07A1001AAGY - Country ref. BAAP07A1001AAGY
- Colour: Grey
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 2.5 mm²
- Maximum Pulling Tension: 0.18 kN
- Minimum Bend Radius - During Installation (under Tension): 22 mm
- Minimum Bend Radius - Installed: 14 mm
2.5mm2 PVC Building Wire Red 100m
Nexans ref. BAAP07A1001AARD - Country ref. BAAP07A1001AARD
- Colour: Red
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 2.5 mm²
- Maximum Pulling Tension: 0.18 kN
- Minimum Bend Radius - During Installation (under Tension): 22 mm
- Minimum Bend Radius - Installed: 14 mm
2.5mm2 PVC Building Wire Red 500m
Nexans ref. BAAP07A5001AARD - Country ref. BAAP07A5001AARD
- Colour: Red
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 2.5 mm²
- Maximum Pulling Tension: 0.18 kN
- Minimum Bend Radius - During Installation (under Tension): 22 mm
- Minimum Bend Radius - Installed: 14 mm
2.5mm2 PVC Building Wire White 100m
Nexans ref. BAAP07A1001AAWT - Country ref. BAAP07A1001AAWT
- Colour: White
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 2.5 mm²
- Maximum Pulling Tension: 0.18 kN
- Minimum Bend Radius - During Installation (under Tension): 22 mm
- Minimum Bend Radius - Installed: 14 mm
2.5mm2 PVC Building Wire White 500m
Nexans ref. BAAP07A5001AAWT - Country ref. BAAP07A5001AAWT
- Colour: White
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 2.5 mm²
- Maximum Pulling Tension: 0.18 kN
- Minimum Bend Radius - During Installation (under Tension): 22 mm
- Minimum Bend Radius - Installed: 14 mm
240mm2 PVC Building Wire Green/Yellow
Nexans ref. BAAP26AA001AAHN - Country ref. BAAP26AA001AAHN
- Packaging: Cut to length (m)
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: - m
- Conductor cross-section: 240 mm²
- Maximum Pulling Tension: 17 kN
- Minimum Bend Radius - During Installation (under Tension): 280 mm
- Minimum Bend Radius - Installed: 150 mm
25mm2 PVC Building Wire Black
Nexans ref. BAAC17AA001AABK - Country ref. BAAC17AA001AABK
- Packaging: Cut to length (m)
- Colour: Black
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: - m
- Conductor cross-section: 25 mm²
- Maximum Pulling Tension: 1.8 kN
- Minimum Bend Radius - During Installation (under Tension): 100 mm
- Minimum Bend Radius - Installed: 67 mm
25mm2 PVC Building Wire Black 500m
Nexans ref. BAAC17A5001AABK - Country ref. BAAC17A5001AABK
- Colour: Black
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: 500 m
- Conductor cross-section: 25 mm²
- Maximum Pulling Tension: 1.8 kN
- Minimum Bend Radius - During Installation (under Tension): 100 mm
- Minimum Bend Radius - Installed: 67 mm
25mm2 PVC Building Wire Green/Yellow
Nexans ref. BAAC17AA001AAHN - Country ref. BAAC17AA001AAHN
- Packaging: Cut to length (m)
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: - m
- Conductor cross-section: 25 mm²
- Maximum Pulling Tension: 1.8 kN
- Minimum Bend Radius - During Installation (under Tension): 100 mm
- Minimum Bend Radius - Installed: 67 mm
25mm2 PVC Building Wire Green/Yellow 100m
Nexans ref. BAAC17A1001AAHN - Country ref. BAAC17A1001AAHN
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: 100 m
- Conductor cross-section: 25 mm²
- Maximum Pulling Tension: 1.8 kN
- Minimum Bend Radius - During Installation (under Tension): 101 mm
- Minimum Bend Radius - Installed: 67 mm
25mm2 PVC Building Wire Green/Yellow 500m
Nexans ref. BAAC17A5001AAHN - Country ref. BAAC17A5001AAHN
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: 500 m
- Conductor cross-section: 25 mm²
- Maximum Pulling Tension: 1.8 kN
- Minimum Bend Radius - During Installation (under Tension): 100 mm
- Minimum Bend Radius - Installed: 67 mm
25mm2 PVC Building Wire Red
Nexans ref. BAAC17AA001AARD - Country ref. BAAC17AA001AARD
- Packaging: Cut to length (m)
- Colour: Red
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: - m
- Conductor cross-section: 25 mm²
- Maximum Pulling Tension: 1.8 kN
- Minimum Bend Radius - During Installation (under Tension): 100 mm
- Minimum Bend Radius - Installed: 67 mm
25mm2 PVC Building Wire Red 500m
Nexans ref. BAAC17A5001AARD - Country ref. BAAC17A5001AARD
- Colour: Red
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: 500 m
- Conductor cross-section: 25 mm²
- Maximum Pulling Tension: 1.8 kN
- Minimum Bend Radius - During Installation (under Tension): 100 mm
- Minimum Bend Radius - Installed: 67 mm
25mm2 PVC Building Wire White
Nexans ref. BAAC17AA001AAWT - Country ref. BAAC17AA001AAWT
- Packaging: Cut to length (m)
- Colour: White
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: - m
- Conductor cross-section: 25 mm²
- Maximum Pulling Tension: 1.8 kN
- Minimum Bend Radius - During Installation (under Tension): 100 mm
- Minimum Bend Radius - Installed: 67 mm
35mm2 PVC Building Wire Black 100m
Nexans ref. BAAC18A1001AABK - Country ref. BAAC18A1001AABK
- Colour: Black
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: 100 m
- Conductor cross-section: 35 mm²
- Maximum Pulling Tension: 2.5 kN
- Minimum Bend Radius - During Installation (under Tension): 110 mm
- Minimum Bend Radius - Installed: 75 mm
35mm2 PVC Building Wire Blue
Nexans ref. BAAC18AA001AABE - Country ref. BAAC18AA001AABE
- Packaging: Cut to length (m)
- Colour: Blue
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: - m
- Conductor cross-section: 35 mm²
- Maximum Pulling Tension: 2.5 kN
- Minimum Bend Radius - During Installation (under Tension): 110 mm
- Minimum Bend Radius - Installed: 75 mm
35mm2 PVC Building Wire Green/Yellow
Nexans ref. BAAC18AA001AAHN - Country ref. BAAC18AA001AAHN
- Packaging: Cut to length (m)
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: - m
- Conductor cross-section: 35 mm²
- Maximum Pulling Tension: 2.5 kN
- Minimum Bend Radius - During Installation (under Tension): 110 mm
- Minimum Bend Radius - Installed: 75 mm
35mm2 PVC Building Wire Green/Yellow 100m
Nexans ref. BAAC18A1001AAHN - Country ref. BAAC18A1001AAHN
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: 100 m
- Conductor cross-section: 35 mm²
- Maximum Pulling Tension: 2.5 kN
- Minimum Bend Radius - During Installation (under Tension): 110 mm
- Minimum Bend Radius - Installed: 75 mm
35mm2 PVC Building Wire Green/Yellow 500m
Nexans ref. BAAC18A5001AAHN - Country ref. BAAC18A5001AAHN
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: 500 m
- Conductor cross-section: 35 mm²
- Maximum Pulling Tension: 2.5 kN
- Minimum Bend Radius - During Installation (under Tension): 110 mm
- Minimum Bend Radius - Installed: 75 mm
35mm2 PVC Building Wire Red
Nexans ref. BAAC18AA001AARD - Country ref. BAAC18AA001AARD
- Packaging: Cut to length (m)
- Colour: Red
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: - m
- Conductor cross-section: 35 mm²
- Maximum Pulling Tension: 2.5 kN
- Minimum Bend Radius - During Installation (under Tension): 110 mm
- Minimum Bend Radius - Installed: 75 mm
4mm2 PVC Building Wire Black 100m
Nexans ref. BAAP09A1001AABK - Country ref. BAAP09A1001AABK
- Colour: Black
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 4 mm²
- Maximum Pulling Tension: 0.28 kN
- Minimum Bend Radius - During Installation (under Tension): 27 mm
- Minimum Bend Radius - Installed: 18 mm
4mm2 PVC Building Wire Black 500m
Nexans ref. BAAP09A5001AABK - Country ref. BAAP09A5001AABK
- Colour: Black
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 4 mm²
- Maximum Pulling Tension: 0.28 kN
- Minimum Bend Radius - During Installation (under Tension): 27 mm
- Minimum Bend Radius - Installed: 18 mm
4mm2 PVC Building Wire Blue 100m
Nexans ref. BAAP09A1001AABE - Country ref. BAAP09A1001AABE
- Colour: Blue
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 4 mm²
- Maximum Pulling Tension: 0.28 kN
- Minimum Bend Radius - During Installation (under Tension): 27 mm
- Minimum Bend Radius - Installed: 18 mm
4mm2 PVC Building Wire Blue 500m
Nexans ref. BAAP09A5001AABE - Country ref. BAAP09A5001AABE
- Colour: Blue
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 4 mm²
- Maximum Pulling Tension: 0.28 kN
- Minimum Bend Radius - During Installation (under Tension): 27 mm
- Minimum Bend Radius - Installed: 18 mm
4mm2 PVC Building Wire Green/Yellow 100m
Nexans ref. BAAP09A1001AAHN - Country ref. BAAP09A1001AAHN
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 4 mm²
- Maximum Pulling Tension: 0.28 kN
- Minimum Bend Radius - During Installation (under Tension): 27 mm
- Minimum Bend Radius - Installed: 18 mm
4mm2 PVC Building Wire Green/Yellow 500m
Nexans ref. BAAP09A5001AAHN - Country ref. BAAP09A5001AAHN
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 4 mm²
- Maximum Pulling Tension: 0.28 kN
- Minimum Bend Radius - During Installation (under Tension): 27 mm
- Minimum Bend Radius - Installed: 18 mm
4mm2 PVC Building Wire Red 100m
Nexans ref. BAAP09A1001AARD - Country ref. BAAP09A1001AARD
- Colour: Red
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 4 mm²
- Maximum Pulling Tension: 0.28 kN
- Minimum Bend Radius - During Installation (under Tension): 27 mm
- Minimum Bend Radius - Installed: 18 mm
4mm2 PVC Building Wire Red 500m
Nexans ref. BAAP09A5001AARD - Country ref. BAAP09A5001AARD
- Colour: Red
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 4 mm²
- Maximum Pulling Tension: 0.28 kN
- Minimum Bend Radius - During Installation (under Tension): 27 mm
- Minimum Bend Radius - Installed: 18 mm
4mm2 PVC Building Wire White 100m
Nexans ref. BAAP09A1001AAWT - Country ref. BAAP09A1001AAWT
- Colour: White
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 4 mm²
- Maximum Pulling Tension: 0.28 kN
- Minimum Bend Radius - During Installation (under Tension): 27 mm
- Minimum Bend Radius - Installed: 18 mm
50mm2 PVC Building Wire Green/Yellow
Nexans ref. BAAC19AA001AAHN - Country ref. BAAC19AA001AAHN
- Packaging: Cut to length (m)
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: - m
- Conductor cross-section: 50 mm²
- Maximum Pulling Tension: 3.5 kN
- Minimum Bend Radius - During Installation (under Tension): 130 mm
- Minimum Bend Radius - Installed: 87 mm
50mm2 PVC Building Wire White
Nexans ref. BAAC19AA001AAWT - Country ref. BAAC19AA001AAWT
- Packaging: Cut to length (m)
- Colour: White
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: - m
- Conductor cross-section: 50 mm²
- Maximum Pulling Tension: 3.5 kN
- Minimum Bend Radius - During Installation (under Tension): 130 mm
- Minimum Bend Radius - Installed: 87 mm
6mm2 PVC Building Wire Black 100m
Nexans ref. BAAP11A1001AABK - Country ref. BAAP11A1001AABK
- Colour: Black
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 6 mm²
- Maximum Pulling Tension: 0.42 kN
- Minimum Bend Radius - During Installation (under Tension): 31 mm
- Minimum Bend Radius - Installed: 20 mm
6mm2 PVC Building Wire Black 500m
Nexans ref. BAAP11A5001AABK - Country ref. BAAP11A5001AABK
- Colour: Black
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 6 mm²
- Maximum Pulling Tension: 0.42 kN
- Minimum Bend Radius - During Installation (under Tension): 31 mm
- Minimum Bend Radius - Installed: 20 mm
6mm2 PVC Building Wire Blue 100m
Nexans ref. BAAP11A1001AABE - Country ref. BAAP11A1001AABE
- Colour: Blue
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 6 mm²
- Maximum Pulling Tension: 0.42 kN
- Minimum Bend Radius - During Installation (under Tension): 31 mm
- Minimum Bend Radius - Installed: 20 mm
6mm2 PVC Building Wire Blue 500m
Nexans ref. BAAP11A5001AABE - Country ref. BAAP11A5001AABE
- Colour: Blue
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 6 mm²
- Maximum Pulling Tension: 0.42 kN
- Minimum Bend Radius - During Installation (under Tension): 31 mm
- Minimum Bend Radius - Installed: 20 mm
6mm2 PVC Building Wire Green/Yellow 100m
Nexans ref. BAAP11A1001AAHN - Country ref. BAAP11A1001AAHN
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 6 mm²
- Maximum Pulling Tension: 0.42 kN
- Minimum Bend Radius - During Installation (under Tension): 31 mm
- Minimum Bend Radius - Installed: 20 mm
6mm2 PVC Building Wire Green/Yellow 500m
Nexans ref. BAAP11A5001AAHN - Country ref. BAAP11A5001AAHN
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 6 mm²
- Maximum Pulling Tension: 0.42 kN
- Minimum Bend Radius - During Installation (under Tension): 31 mm
- Minimum Bend Radius - Installed: 20 mm
6mm2 PVC Building Wire Grey 100m
Nexans ref. BAAP11A1001AAGY - Country ref. BAAP11A1001AAGY
- Colour: Grey
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 6 mm²
- Maximum Pulling Tension: 0.42 kN
- Minimum Bend Radius - During Installation (under Tension): 31 mm
- Minimum Bend Radius - Installed: 20 mm
6mm2 PVC Building Wire Red 100m
Nexans ref. BAAP11A1001AARD - Country ref. BAAP11A1001AARD
- Colour: Red
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 6 mm²
- Maximum Pulling Tension: 0.42 kN
- Minimum Bend Radius - During Installation (under Tension): 31 mm
- Minimum Bend Radius - Installed: 20 mm
6mm2 PVC Building Wire Red 500m
Nexans ref. BAAP11A5001AARD - Country ref. BAAP11A5001AARD
- Colour: Red
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 6 mm²
- Maximum Pulling Tension: 0.42 kN
- Minimum Bend Radius - During Installation (under Tension): 31 mm
- Minimum Bend Radius - Installed: 20 mm
6mm2 PVC Building Wire White 100m
Nexans ref. BAAP11A1001AAWT - Country ref. BAAP11A1001AAWT
- Colour: White
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 6 mm²
- Maximum Pulling Tension: 0.42 kN
- Minimum Bend Radius - During Installation (under Tension): 31 mm
- Minimum Bend Radius - Installed: 20 mm
6mm2 PVC Building Wire White 500m
Nexans ref. BAAP11A5001AAWT - Country ref. BAAP11A5001AAWT
- Colour: White
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 500 m
- Conductor cross-section: 6 mm²
- Maximum Pulling Tension: 0.42 kN
- Minimum Bend Radius - During Installation (under Tension): 31 mm
- Minimum Bend Radius - Installed: 20 mm
70mm2 PVC Building Wire Black
Nexans ref. BAAC20AA001AABK - Country ref. BAAC20AA001AABK
- Packaging: Cut to length (m)
- Colour: Black
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: - m
- Conductor cross-section: 70 mm²
- Maximum Pulling Tension: 4.9 kN
- Minimum Bend Radius - During Installation (under Tension): 150 mm
- Minimum Bend Radius - Installed: 100 mm
70mm2 PVC Building Wire Black 100m
Nexans ref. BAAC20A1001AABK - Country ref. BAAC20A1001AABK
- Colour: Black
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: 100 m
- Conductor cross-section: 70 mm²
- Maximum Pulling Tension: 4.9 kN
- Minimum Bend Radius - During Installation (under Tension): 150 mm
- Minimum Bend Radius - Installed: 99 mm
70mm2 PVC Building Wire Green/Yellow
Nexans ref. BAAC20AA001AAHN - Country ref. BAAC20AA001AAHN
- Packaging: Cut to length (m)
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: - m
- Conductor cross-section: 70 mm²
- Maximum Pulling Tension: 4.9 kN
- Minimum Bend Radius - During Installation (under Tension): 150 mm
- Minimum Bend Radius - Installed: 120 mm
70mm2 PVC Building Wire Green/Yellow 500m
Nexans ref. BAAC20A5001AAHN - Country ref. BAAC20A5001AAHN
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: 500 m
- Conductor cross-section: 70 mm²
- Maximum Pulling Tension: 4.9 kN
- Minimum Bend Radius - During Installation (under Tension): 150 mm
- Minimum Bend Radius - Installed: 100 mm
95mm2 PVC Building Wire Black
Nexans ref. BAAC22AA001AABK - Country ref. BAAC22AA001AABK
- Packaging: Cut to length (m)
- Colour: Black
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: - m
- Conductor cross-section: 95 mm²
- Maximum Pulling Tension: 6.7 kN
- Minimum Bend Radius - During Installation (under Tension): 180 mm
- Minimum Bend Radius - Installed: 120 mm
95mm2 PVC Building Wire Green/Yellow
Nexans ref. BAAC22AA001AAHN - Country ref. BAAC22AA001AAHN
- Packaging: Cut to length (m)
- Colour: Green / yellow
- Conductor flexibility: Class 2
- Type of conductor: Compact copper
- Cable length: - m
- Conductor cross-section: 95 mm²
- Maximum Pulling Tension: 6.7 kN
- Minimum Bend Radius - During Installation (under Tension): 180 mm
- Minimum Bend Radius - Installed: 130 mm
CU CONDUIT 16 BK V75 1HM
Nexans ref. BAAP15A1001AABK - Country ref. BAAP15A1001AABK
- Colour: Black
- Conductor flexibility: Class 2
- Type of conductor: Stranded copper
- Cable length: 100 m
- Conductor cross-section: 16 mm²
- Maximum Pulling Tension: 1.1 kN
- Minimum Bend Radius - During Installation (under Tension): 41 mm
- Minimum Bend Radius - Installed: 28 mm
Description
Description
Standards
-
ProductAS/NZS 1125; AS/NZS 5000.1
Single Core Building Wires
- Single core,
- 0.6/1kV V-90 insulated,
- to AS/NZS 5000.1 (unsheathed),
- Copper conductors, 90°C.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Resources
Resources
PVC Insulated - Current carrying capacity table single phase (in Amps)
Copper Conductor
Insulation PVC
Maximum Conductor Temperature 75⁰C
Conductor cross-section |
|
|
|
|
|
|
|
|
---|---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
1.0 | 16.0 | 16.0 | 13.0 | 13.0 | 11.0 | 6.0 | 18.0 | 21.0 |
1.5 | 21.0 | 21.0 | 16.0 | 18.0 | 14.0 | 8.0 | 23.0 | 26.0 |
2.5 | 30.0 | 29.0 | 23.0 | 24.0 | 20.0 | 12.0 | 32.0 | 36.0 |
4.0 | 40.0 | 39.0 | 31.0 | 32.0 | 25.0 | 16.0 | 41.0 | 47.0 |
6.0 | 51.0 | 49.0 | 40.0 | 41.0 | 33.0 | 20.0 | 52.0 | 58.0 |
10.0 | 69.0 | 67.0 | 54.0 | 54.0 | 44.0 | 27.0 | 69.0 | 77.0 |
16.0 | 92.0 | 89.0 | 72.0 | 70.0 | 56.0 | 36.0 | 89.0 | 99.0 |
25.0 | 124.0 | 119.0 | 97.0 | 94.0 | 75.0 | 48.0 | 116.0 | 129.0 |
35.0 | 153.0 | 145.0 | 119.0 | 112.0 | 90.0 | 59.0 | 139.0 | 155.0 |
50.0 | 187.0 | 177.0 | 146.0 | 138.0 | 110.0 | 0.0 | 168.0 | 186.0 |
70.0 | 238.0 | 223.0 | 184.0 | 170.0 | 136.0 | 0.0 | 206.0 | 228.0 |
95.0 | 295.0 | 276.0 | 230.0 | 212.0 | 169.0 | 0.0 | 252.0 | 278.0 |
120.0 | 344.0 | 321.0 | 267.0 | 242.0 | 193.0 | 0.0 | 287.0 | 316.0 |
150.0 | 395.0 | 367.0 | 308.0 | 282.0 | 225.0 | 0.0 | 329.0 | 354.0 |
185.0 | 459.0 | 424.0 | 358.0 | 320.0 | 256.0 | 0.0 | 373.0 | 408.0 |
240.0 | 549.0 | 505.0 | 428.0 | 381.0 | 305.0 | 0.0 | 438.0 | 472.0 |
300.0 | 636.0 | 582.0 | 495.0 | 0.0 | 0.0 | 0.0 | 496.0 | 546.0 |
400.0 | 744.0 | 676.0 | 577.0 | 0.0 | 0.0 | 0.0 | 575.0 | 621.0 |
500.0 | 867.0 | 780.0 | 668.0 | 0.0 | 0.0 | 0.0 | 649.0 | 721.0 |
630.0 | 1014.0 | 897.0 | 770.0 | 0.0 | 0.0 | 0.0 | 750.0 | 816.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Underground ducts A - Undergound Wiring Enclosure |
Underground ducts B - Individual Wiring Enclosure |
PVC Insulated - Current carrying capacity table three phase (in Amps)
Copper Conductor
Insulation PVC
Maximum Conductor Temperature 75⁰C
Conductor cross-section |
|
|
|
|
|
|
|
|
---|---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
1.0 | 16.0 | 14.0 | 13.0 | 12.0 | 10.0 | 6.0 | 16.0 | 19.0 |
1.5 | 20.0 | 17.0 | 16.0 | 15.0 | 12.0 | 8.0 | 20.0 | 24.0 |
2.5 | 29.0 | 25.0 | 23.0 | 21.0 | 17.0 | 12.0 | 27.0 | 33.0 |
4.0 | 38.0 | 33.0 | 31.0 | 28.0 | 23.0 | 16.0 | 36.0 | 43.0 |
6.0 | 49.0 | 42.0 | 40.0 | 35.0 | 28.0 | 20.0 | 45.0 | 53.0 |
10.0 | 67.0 | 58.0 | 54.0 | 47.0 | 37.0 | 27.0 | 59.0 | 70.0 |
16.0 | 89.0 | 77.0 | 72.0 | 62.0 | 50.0 | 36.0 | 78.0 | 90.0 |
25.0 | 120.0 | 103.0 | 97.0 | 81.0 | 64.0 | 48.0 | 100.0 | 117.0 |
35.0 | 148.0 | 127.0 | 119.0 | 100.0 | 80.0 | 59.0 | 122.0 | 140.0 |
50.0 | 181.0 | 156.0 | 146.0 | 119.0 | 95.0 | 0.0 | 144.0 | 168.0 |
70.0 | 230.0 | 197.0 | 184.0 | 152.0 | 122.0 | 0.0 | 180.0 | 205.0 |
95.0 | 287.0 | 246.0 | 230.0 | 183.0 | 147.0 | 0.0 | 217.0 | 250.0 |
120.0 | 335.0 | 287.0 | 267.0 | 217.0 | 173.0 | 0.0 | 252.0 | 283.0 |
150.0 | 385.0 | 330.0 | 308.0 | 244.0 | 195.0 | 0.0 | 283.0 | 317.0 |
185.0 | 447.0 | 383.0 | 357.0 | 284.0 | 227.0 | 0.0 | 325.0 | 365.0 |
240.0 | 535.0 | 457.0 | 426.0 | 331.0 | 265.0 | 0.0 | 377.0 | 422.0 |
300.0 | 620.0 | 529.0 | 492.0 | 388.0 | 311.0 | 0.0 | 434.0 | 488.0 |
400.0 | 726.0 | 615.0 | 573.0 | 442.0 | 353.0 | 0.0 | 492.0 | 553.0 |
500.0 | 846.0 | 710.0 | 661.0 | 523.0 | 418.0 | 0.0 | 571.0 | 641.0 |
630.0 | 990.0 | 817.0 | 760.0 | 588.0 | 471.0 | 0.0 | 639.0 | 723.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Underground ducts A - Undergound Wiring Enclosure |
Underground ducts B - Individual Wiring Enclosure |
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania