- Products
- Market Solutions & Services
- Insight
- Tools & Resources
- About Nexans Australia
- Search
- Contact us
- Compare
- Sign in
25mm2 PVC Building Wire Green/Yellow 100m
25mm2 PVC Building Wire Green/Yellow 100m
25mm2 PVC Building Wire Green/Yellow
Read more- Nexans ref. : BAAC17A1001AAHN
- EAN : 9319215264239
Description
Description
Standards
-
NationalAS/NZS 1125; AS/NZS 5000.1
Single Core Building Wires
- Single core,
- 0.6/1kV V-90 insulated,
- to AS/NZS 5000.1 (unsheathed),
- Copper conductors, 90°C.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Colour
Green / yellow
Conductor flexibility
Class 2
Conductor material
Copper
Conductor shape
Circular
Insulation
V-90
Type of conductor
Compact copper
With Green/Yellow core
Yes
Dimensional characteristics
Dimensional characteristics
Approximate weight
26.0 kg/100m
Cable length
100 m
Conductor cross-section
25 mm²
Neutral conductor section (when smaller)
- mm²
Nominal insulation thickness
1.2 mm
Nominal overall diameter
8.4 mm
Number of cores
1
Electrical characteristics
Electrical characteristics
Conductor AC resistance at 50 Hz
0.884 Ohm/km
Inductive reactance at 50Hz - flat touching
0.121 Ohm/km
Inductive reactance at 50Hz - trefoil
0.106 Ohm/km
Insulation resistance at 20°C
5.9 MOhm.km
Max. DC resistance of the conductor at 20°C
0.727 Ohm/km
Rated Voltage Uo/U (Um)
0,6/1 kV
Mechanical characteristics
Mechanical characteristics
Cable flexibility
Rigid
Maximum Pulling Tension
1.8 kN
Usage characteristics
Usage characteristics
Minimum Bend Radius - During Installation (under Tension)
101 mm
Minimum Bend Radius - Installed
67 mm
Resources
Resources
PVC Insulated - Current carrying capacity table single phase (in Amps)
Copper Conductor Insulation PVC Maximum Conductor Temperature 75⁰CConductor cross-section | ||||||||
---|---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
25.0 | 124.0 | 119.0 | 97.0 | 94.0 | 75.0 | 48.0 | 116.0 | 129.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Underground ducts A - Undergound Wiring Enclosure |
Underground ducts B - Individual Wiring Enclosure |
PVC Insulated - Current carrying capacity table three phase (in Amps)
Copper Conductor Insulation PVC Maximum Conductor Temperature 75⁰CConductor cross-section | ||||||||
---|---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
25.0 | 120.0 | 103.0 | 97.0 | 81.0 | 64.0 | 48.0 | 100.0 | 117.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Underground ducts A - Undergound Wiring Enclosure |