3C 300mm2 Cu 19/33kV PVC Black

Description

Description

Standards

  • International
    IEC 60228; IEC 60502-2
  • National
    AS/NZS 1125; AS/NZS 1429.1

Construction

  • Stranded compacted conductor
  • Semi-conductive insulation screen
  • Copper wire screen
  • XLPE insulation
  • Semi-conductive conductor screen
  • FIllers
  • PVC sheath

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Armour type
-
Conductor flexibility
Class 2
Conductor material
Copper
Conductor shape
Circular
Insulation
XLPE
Outer sheath
PVC
Screen
Copper wire
Type of conductor
Stranded compacted

Dimensional characteristics

Dimensional characteristics

Approximate weight
1410.0 kg/100m
Conductor cross-section
300 mm²
Conductor diameter
20.7 mm
Diameter over insulation
38.416 mm
Diameter over screen
41.916 mm
Nominal Duct Diameter
150 mm
Nominal Screen Area on each core
68.09 mm²
Nominal insulation thickness
8.0 mm
Nominal overall diameter
99.4 mm
Nominal overall diameter
-
Number of screen wires (nb x mm Ø)
40 x 0.85 mm Ø

Electrical characteristics

Electrical characteristics

A.C. Conductor resist. 50Hz and at 90 °C
0.079 Ohm/km
Capacitance (All Main Cores - Screen)
0.247 µF / km
Charging current per phase
1.475 A/km
DC Resistance of the Screen at 20°C
0.27 Ohm/km
Dielectric loss per phase
112 W/km
Inductive reactance at 50Hz
0.107 Ohm/km
Insulation resistance at 20°C
9800 MOhm.km
Max. DC resistance of the conductor at 20°C
0.06 Ohm/km
Maximum electric stress
3.1 kV/mm
Permissible short circuit current conductor 1s
42.9 kA
Permissible short circuit current screen 1s
10.1 kA
Rated Voltage Uo/U (Um)
-
Zero sequence reactance at 50HZ
0.06 Ohm/km
Zero sequence resistance at 20°C
0.858 Ohm/km

Mechanical characteristics

Mechanical characteristics

Maximum Pulling Tension
63 kN

Usage characteristics

Usage characteristics

Minimum Bend Radius - During Installation (under Tension)
1790 mm
Minimum Bend Radius - Installed
1190 mm

Resources

Resources

Current carrying capacity table (in Amps) - 19/33kV Three Core

Current carrying capacity table (in Amps) - 19/33kV Three Core
Conductor cross-section
mm² Cu Al Cu Al Cu Al Cu Al Cu Al
300.0 609.0 472.0 658.0 509.0 456.0 354.0 563.0 438.0 478.0 372.0
In air touching (3 core)
In air spaced (3 core)
In air enclosed (3 core)
Underground Direct Buried (3 core)
Underground ducts (3 core)

Dealer locator

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close