3C 70mm2 Al 19/33kV PVC Black

Description

Description

Standards

  • Product
    AS/NZS 1125; AS/NZS 1429.1; IEC 60228; IEC 60502-2

Construction

  • Stranded compacted conductor
  • Semi-conductive insulation screen
  • Copper wire screen
  • XLPE insulation
  • Semi-conductive conductor screen
  • FIllers
  • PVC sheath

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Armour type
-
Conductor flexibility
Class 2
Conductor material
Aluminum
Conductor shape
Circular
Insulation
XLPE
Outer sheath
PVC
Screen
Copper wire
Type of conductor
Stranded compacted

Dimensional characteristics

Dimensional characteristics

Approximate weight
415.0 kg/100m
Conductor cross-section
70 mm²
Conductor diameter
9.65 mm
Diameter over insulation
27.166 mm
Diameter over screen
30.466 mm
Nominal Duct Diameter
125 mm
Nominal Screen Area on each core
45.96 mm²
Nominal insulation thickness
8.0 mm
Nominal overall diameter
73.1 mm
Nominal overall diameter
-
Number of screen wires (nb x mm Ø)
27 x 0.85 mm Ø

Electrical characteristics

Electrical characteristics

A.C. Conductor resist. 50Hz and at 90 °C
0.568 Ohm/km
Capacitance (All Main Cores - Screen)
0.148 µF / km
Charging current per phase
0.885 A/km
DC Resistance of the Screen at 20°C
0.39 Ohm/km
Dielectric loss per phase
67.3 W/km
Inductive reactance at 50Hz
0.136 Ohm/km
Insulation resistance at 20°C
16000 MOhm.km
Max. DC resistance of the conductor at 20°C
0.443 Ohm/km
Maximum electric stress
3.8 kV/mm
Permissible short circuit current conductor 1s
6.6 kA
Permissible short circuit current screen 1s
6.82 kA
Rated Voltage Uo/U (Um)
-
Zero sequence reactance at 50HZ
0.088 Ohm/km
Zero sequence resistance at 20°C
1.62 Ohm/km

Mechanical characteristics

Mechanical characteristics

Maximum Pulling Tension
10.5 kN

Usage characteristics

Usage characteristics

Minimum Bend Radius - During Installation (under Tension)
1320 mm
Minimum Bend Radius - Installed
880 mm

Resources

Resources

Current carrying capacity table (in Amps) - 19/33kV Three Core

Current carrying capacity table (in Amps) - 19/33kV Three Core
Conductor cross-section
mm² Cu Al Cu Al Cu Al Cu Al Cu Al
70.0 252.0 196.0 269.0 209.0 198.0 153.0 250.0 194.0 213.0 165.0
In air touching (3 core)
In air spaced (3 core)
In air enclosed (3 core)
Underground Direct Buried (3 core)
Underground ducts (3 core)

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close