19/33kV Three Core SWA
19/33kV Three Core SWA
19/33kV Three Core, Individually Screened and PVC Sheathed Stranded Conductors up to 10kA fault level
Read more- Nexans ref. : XNJP19AA003JBAA
- Country ref. : XNJP19AA003JBAA
- EAN : 9319215453251
Description
Description
Standards
-
ProductAS/NZS 1125; AS/NZS 1429.1; IEC 60228; IEC 60502-2
Construction
- Stranded compacted conductor
- Triple extruded conductor screen
- Insulation and insulation screen
- Copper wire screened
- Steel wire armoured
- PVC sheathed
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Armour type
Galvanized steel wires
Conductor material
Copper
Insulation
XLPE
Material of bedding
PVC
Outer sheath
PVC
Screen
Copper wire
Type of conductor
Stranded compacted
Dimensional characteristics
Dimensional characteristics
Approximate weight
950.0 kg/100m
Conductor cross-section
50 mm²
Conductor diameter
8.0 mm
Diameter over armour
72.8 mm
Diameter over insulation
25.5 mm
Diameter over screen
28.8 mm
Nominal Duct Diameter
125 mm
Nominal Screen Area on each core
49.4 mm²
Nominal armour wire diameter
3.15 mm
Nominal diameter over bedding
66.5 mm
Nominal insulation thickness
8.0 mm
Nominal overall diameter
80.1 mm
Number of screen wires (nb x mm Ø)
29 x 0.85 mm Ø
Electrical characteristics
Electrical characteristics
A.C. Conductor resist. 50Hz and at 90 °C
0.494 Ohm/km
Armour DC resistance at 20°C
0.302 Ohm/km
Capacitance (All Main Cores - Screen)
0.133 µF / km
Charging current per phase
0.796 A/km
DC Resistance of the Screen at 20°C
0.37 Ohm/km
Dielectric loss per phase
60.5 W/km
Inductive reactance at 50Hz
0.147 Ohm/km
Insulation resistance at 20°C
18000 MOhm.km
Max. DC resistance of the conductor at 20°C
0.387 Ohm/km
Maximum electric stress
4 kV/mm
Permissible short circuit current conductor 1s
7.1 kA
Permissible short circuit current screen 1s
7.32 kA
Rated Voltage Uo/U (Um)
-
Zero sequence reactance at 50HZ
0.152 Ohm/km
Zero sequence resistance at 20°C
0.884 Ohm/km
Mechanical characteristics
Mechanical characteristics
Maximum Pull Tension of Armour
64 kN
Maximum Pull Tension of Conductor
11 kN
Usage characteristics
Usage characteristics
Minimum Bend Radius - During Installation (under Tension)
1440 mm
Minimum Bend Radius - Installed
960 mm
Resources
Resources
Current carrying capacity table (in Amps) - 19/33kV Three Core SWA
Current carrying capacity table (in Amps) - 19/33kV Three Core SWAConductor cross-section |
|
|
|
|
|
|||||
---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
50.0 | 202.0 | 157.0 | 215.0 | 167.0 | 161.0 | 125.0 | 201.0 | 157.0 | 173.0 | 135.0 |
In air touching (3 core) |
In air spaced (3 core) |
In air enclosed (3 core) |
Underground Direct Buried (3 core) |
Underground ducts (3 core) |
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania