VAROLEX® VSD 3C+3E 90°C - Flexible for Fixed Application

Products

3X1.5mm2 + E Flex Varolex Black

Nexans ref. FTDR04AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 1.5 mm²
  • Conductor cross-section: 1.5 mm²
  • Number of earth cores: 1
  • Maximum Pulling Tension: 0.64 kN
  • Minimum Bend Radius - During Installation (under Tension): 243 mm
  • Minimum Bend Radius - Installed: 162 mm

 

3X2.5mm2 + E Flex Varolex Black

Nexans ref. FTDR05AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 2.5 mm²
  • Conductor cross-section: 2.5 mm²
  • Number of earth cores: 1
  • Maximum Pulling Tension: 0.75 kN
  • Minimum Bend Radius - During Installation (under Tension): 262.8 mm
  • Minimum Bend Radius - Installed: 175.2 mm

 

3X4mm2 + 3E Flex Varolex Black

Nexans ref. FTDR06AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 4.5 mm²
  • Conductor cross-section: 4 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 0.99 kN
  • Minimum Bend Radius - During Installation (under Tension): 302.4 mm
  • Minimum Bend Radius - Installed: 201.6 mm

 

3X6mm2 + 3E Flex Varolex Black

Nexans ref. FTDR07AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 4.5 mm²
  • Conductor cross-section: 6 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 1.1 kN
  • Minimum Bend Radius - During Installation (under Tension): 318.6 mm
  • Minimum Bend Radius - Installed: 212.4 mm

 

3X10mm2 + 3E Flex Varolex Black

Nexans ref. FTDX01AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 4.5 mm²
  • Conductor cross-section: 10 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 1.3 kN
  • Minimum Bend Radius - During Installation (under Tension): 347.4 mm
  • Minimum Bend Radius - Installed: 231.6 mm

 

3X16mm2 + 3E Flex Varolex Black

Nexans ref. FTDX02AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 7.5 mm²
  • Conductor cross-section: 16 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 1.63 kN
  • Minimum Bend Radius - During Installation (under Tension): 388.8 mm
  • Minimum Bend Radius - Installed: 259.2 mm

 

3X25mm2 + 3E Flex Varolex Black

Nexans ref. FTDX03AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 12 mm²
  • Conductor cross-section: 25 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 2.1 kN
  • Minimum Bend Radius - During Installation (under Tension): 441 mm
  • Minimum Bend Radius - Installed: 294 mm

 

3X35mm2 + 3E Flex Varolex Black

Nexans ref. FTDX04AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 18 mm²
  • Conductor cross-section: 35 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 2.57 kN
  • Minimum Bend Radius - During Installation (under Tension): 487.8 mm
  • Minimum Bend Radius - Installed: 325.2 mm

 

3X50mm2 + 3E Flex Varolex Black

Nexans ref. FTDX05AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 30 mm²
  • Conductor cross-section: 50 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 3.45 kN
  • Minimum Bend Radius - During Installation (under Tension): 565.2 mm
  • Minimum Bend Radius - Installed: 376.8 mm

 

3X70mm2 + 3E Flex Varolex Black

Nexans ref. FTDX63AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 30 mm²
  • Conductor cross-section: 70 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 4.2 kN
  • Minimum Bend Radius - During Installation (under Tension): 645 mm
  • Minimum Bend Radius - Installed: 430 mm

 

3X95mm2 + 3E Flex Varolex Black

Nexans ref. FTDX64AA003CXRJ

  • Packaging: Reel (m)
  • Combined earth size section: 48 mm²
  • Conductor cross-section: 95 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 5.7 kN
  • Minimum Bend Radius - During Installation (under Tension): 726 mm
  • Minimum Bend Radius - Installed: 484 mm

 

3X120mm2 + 3E Flex Varolex Black

Nexans ref. FTDE87AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 48 mm²
  • Conductor cross-section: 120 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 7.18 kN
  • Minimum Bend Radius - During Installation (under Tension): 815.4 mm
  • Minimum Bend Radius - Installed: 543.6 mm

 

3X150mm2 + 3E Flex Varolex Black

Nexans ref. FTDE88AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 75 mm²
  • Conductor cross-section: 150 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 8.82 kN
  • Minimum Bend Radius - During Installation (under Tension): 903.6 mm
  • Minimum Bend Radius - Installed: 602.4 mm

 

3X185mm2 + 3E Flex Varolex Black

Nexans ref. FTDE89AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 75 mm²
  • Conductor cross-section: 185 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 10.66 kN
  • Minimum Bend Radius - During Installation (under Tension): 993.6 mm
  • Minimum Bend Radius - Installed: 662.4 mm

 

3X240mm2 + 3E Flex Varolex Black

Nexans ref. FTDE90AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 105 mm²
  • Conductor cross-section: 240 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 13.32 kN
  • Minimum Bend Radius - During Installation (under Tension): 1110.6 mm
  • Minimum Bend Radius - Installed: 740.4 mm

 

3X300mm2 + 3E Flex Varolex Black

Nexans ref. FTDE91AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 150 mm²
  • Conductor cross-section: 300 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 16.33 kN
  • Minimum Bend Radius - During Installation (under Tension): 1229.4 mm
  • Minimum Bend Radius - Installed: 819.6 mm

 

Description

Description

Standards

  • National
    AS/NZS 1125; AS/NZS 5000.1
  • Intended for fixed variable speed drive applications
  • 0.6/1kV X-90 insulated,
  • 3 core+3 earths,
  • PVC bedded,
  • Copper tape screened,
  • PVC sheathed to AS/NZS 5000.1,
  • Class 5 and 6 flexible conductor

*For 1.5mm² & 2.5 mm², split earth not feasible, therefore a single earth conductor is utilised.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Class 5
Conductor material
Copper
Conductor shape
Circular
Insulation
X-90
Material of bedding
PVC
Outer sheath
PVC
Screen
Copper tape

Dimensional characteristics

Dimensional characteristics

Number of cores
3

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Maximum operating temperature
90 °C

Resources

Resources

Documentation

Multicore Flexible - Current carrying capacities three phase (in Amps)

Flexible copper conductor

Maximum conductor temperature: 90°C

Reference ambient temperature: 40°C IN AIR, 25°C IN GROUND

Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu Cu Cu
1.0 16.0 15.0 12.0 8.0 14.0 11.0 7.0 23.0 17.0
1.5 20.0 19.0 15.0 10.0 17.0 13.0 8.0 28.0 21.0
2.5 27.0 26.0 20.0 13.0 23.0 18.0 11.0 37.0 28.0
4.0 36.0 34.0 27.0 17.0 29.0 24.0 15.0 49.0 36.0
6.0 46.0 43.0 35.0 22.0 37.0 29.0 18.0 61.0 45.0
10.0 66.0 61.0 49.0 31.0 52.0 42.0 26.0 84.0 62.0
16.0 87.0 81.0 65.0 41.0 67.0 53.0 33.0 108.0 79.0
25.0 116.0 108.0 87.0 54.0 89.0 71.0 44.0 139.0 103.0
35.0 144.0 135.0 108.0 67.0 111.0 89.0 56.0 168.0 127.0
50.0 182.0 170.0 136.0 0.0 136.0 109.0 0.0 206.0 155.0
70.0 230.0 214.0 171.0 0.0 173.0 138.0 0.0 251.0 193.0
95.0 275.0 256.0 205.0 0.0 202.0 162.0 0.0 293.0 226.0
120.0 327.0 303.0 242.0 0.0 242.0 194.0 0.0 337.0 266.0
150.0 375.0 348.0 278.0 0.0 274.0 219.0 0.0 380.0 300.0
185.0 428.0 396.0 317.0 0.0 314.0 251.0 0.0 424.0 339.0
240.0 511.0 472.0 378.0 0.0 379.0 303.0 0.0 493.0 402.0
300.0 584.0 539.0 0.0 0.0 0.0 0.0 0.0 554.0 452.0
400.0 692.0 638.0 0.0 0.0 0.0 0.0 0.0 639.0 537.0
500.0 794.0 730.0 0.0 0.0 0.0 0.0 0.0 716.0 602.0
Unenclosed spaced
Unenclosed touching
Unenclosed and partially surrounded by thermal insulation
Unenclosed and completely surrounded by thermal insulation
Enclosed conduit in air
Enclosed, partially surrounded by thermal insulation
Enclosed, completely surrounded by thermal insulation
Buried direct
Underground Wiring Enclosure

Find a Distributor

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close