- Products
- Market Solutions & Services
- Insight
- Tools & Resources
- About Nexans Australia
- Search
- Contact us
- Compare
- Sign in
300mm2 Al XLPE / PVC SDI Black
300mm2 Al XLPE / PVC SDI Black
300mm2 Al XLPE / PVC SDI Black
Read more- Nexans ref. : BDBA27AA001CXNA
- Country ref. : BDBA27AA001CXNA
- EAN : 99319215280393
Description
Description
Standards
-
ProductAS/NZS 1125; AS/NZS 5000.1
Single core XLPE SDI Cable
- Single core, 0.6/1kV X-90 insulated,
- PVC sheathed to AS/NZS 5000.1,
- Aluminium conductor, 90°C.
Mains; Submains
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Colour
Black
Conductor material
Aluminum
Type of conductor
Circular compacted
Conductor shape
Circular
Conductor flexibility
Class 2
Insulation
X-90
Outer sheath
PVC
Dimensional characteristics
Dimensional characteristics
Approximate weight
112.0 kg/100m
Cable length
- m
Conductor cross-section
300 mm²
Nominal insulation thickness
1.8 mm
Nominal outer sheath thickness
1.8 mm
Nominal overall diameter
27.6 mm
Number of cores
1
Electrical characteristics
Electrical characteristics
Conductor AC resistance at 50 Hz
0.125 Ohm/km
Inductive reactance at 50Hz - flat touching
0.096 Ohm/km
Inductive reactance at 50Hz - trefoil
0.081 Ohm/km
Insulation resistance at 20°C
220 MOhm.km
Max. DC resistance of the conductor at 20°C
0.1 Ohm/km
Rated Voltage Uo/U (Um)
0,6/1 kV
Mechanical characteristics
Mechanical characteristics
Cable flexibility
Rigid
Maximum Pull Tension of Conductor
15 kN
Maximum Pulling Tension
3.3 kN
Usage characteristics
Usage characteristics
Minimum Bend Radius - During Installation (under Tension)
330 mm
Minimum Bend Radius - Installed
220 mm
Resources
Resources
XLPE/PVC single core - Current carrying capacity table single phase (in Amps)
Copper or Aluminium Conductor XLPE Insulation Maximum Conductor Temperature 90⁰CConductor cross-section |
|
|
|
|
|
|
|
|
|
|||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
300.0 | 787.0 | 612.0 | 718.0 | 562.0 | 605.0 | 473.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 711.0 | 556.0 | 562.0 | 440.0 | 620.0 | 482.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Buried direct |
Underground ducts A - Underground Wiring Enclosure |
Underground ducts B - Individual Wiring Enclosure |
XLPE/PVC single core - Current carrying capacity table three phase (in Amps)
Copper or Aluminium Conductor XLPE Insulation Maximum Conductor Temperature 90⁰CConductor cross-section |
|
|
|
|
|
|
|
|
|
|||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
300.0 | 766.0 | 596.0 | 648.0 | 508.0 | 602.0 | 472.0 | 469.0 | 368.0 | 375.0 | 294.0 | 0.0 | 0.0 | 589.0 | 463.0 | 491.0 | 385.0 | 552.0 | 430.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Buried direct |
Underground ducts A - Underground Wiring Enclosure |
Underground ducts B - Individual Wiring Enclosure |
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania