XLP 1X300 PC 0.6/1KV PVC
XLP 1X300 PC 0.6/1KV PVC
300mm2 XLPE / PVC SDI Black
Read more- Nexans ref. : BDBP27AA001CXNA
- Country ref. : BDBP27AA001CXNA
- EAN : 99319215277331
Description
Description
Standards
-
ProductAS/NZS 1125; AS/NZS 5000.1
Single core XLPE SDI Cable
- Single core, 0.6/1kV X-90 insulated,
- PVC sheathed to AS/NZS 5000.1,
- Copper conductor, 90°C.
Mains; Submains
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Colour
Black
Conductor material
Copper
Type of conductor
Compact copper
Conductor shape
Circular
Conductor flexibility
Class 2
Insulation
X-90
Outer sheath
PVC
Dimensional characteristics
Dimensional characteristics
Approximate weight
306.0 kg/100m
Cable length
- m
Conductor cross-section
300 mm²
Nominal insulation thickness
1.8 mm
Nominal outer sheath thickness
1.8 mm
Nominal overall diameter
28.8 mm
Number of cores
1
Electrical characteristics
Electrical characteristics
Conductor AC resistance at 50 Hz
0.077 Ohm/km
Inductive reactance at 50Hz - flat touching
0.096 Ohm/km
Inductive reactance at 50Hz - trefoil
0.081 Ohm/km
Insulation resistance at 20°C
200 MOhm.km
Max. DC resistance of the conductor at 20°C
0.06 Ohm/km
Rated Voltage Uo/U (Um)
0,6/1 kV
Mechanical characteristics
Mechanical characteristics
Cable flexibility
Rigid
Maximum Pull Tension of Conductor
21 kN
Maximum Pulling Tension
3.5 kN
Usage characteristics
Usage characteristics
Minimum Bend Radius - During Installation (under Tension)
350 mm
Minimum Bend Radius - Installed
230 mm
Resources
Resources
XLPE/PVC single core - Current carrying capacity table single phase (in Amps)
Copper or Aluminium Conductor XLPE Insulation Maximum Conductor Temperature 90⁰CConductor cross-section |
|
|
|
|
|
|
|
|
|
|||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
300.0 | 787.0 | 612.0 | 718.0 | 562.0 | 605.0 | 473.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 711.0 | 556.0 | 562.0 | 440.0 | 620.0 | 482.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Buried direct |
Underground ducts A - Underground Wiring Enclosure |
Underground ducts B - Individual Wiring Enclosure |
XLPE/PVC single core - Current carrying capacity table three phase (in Amps)
Copper or Aluminium Conductor XLPE Insulation Maximum Conductor Temperature 90⁰CConductor cross-section |
|
|
|
|
|
|
|
|
|
|||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
300.0 | 766.0 | 596.0 | 648.0 | 508.0 | 602.0 | 472.0 | 469.0 | 368.0 | 375.0 | 294.0 | 0.0 | 0.0 | 589.0 | 463.0 | 491.0 | 385.0 | 552.0 | 430.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Buried direct |
Underground ducts A - Underground Wiring Enclosure |