PVC Orange Circular 2C+E & 3C+E (450/750V & 0.6/1kV)

Products

1.5mm 2C&E 0.6/1kv O/C 500m

Nexans ref. DNHP05A5002OMAA

  • Packaging: Spool (500m)
  • Conductor cross-section: 1.5 mm²
  • Earth conductor cross section: 1.5 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.2 kN
  • Minimum Bend Radius - During Installation (under Tension): 61 mm
  • Minimum Bend Radius - Installed: 40 mm

 

1.5mm 2C&E O/C 450/750V 100m

Nexans ref. CNHP05A1002OMAA

  • Packaging: Spool (100m)
  • Conductor cross-section: 1.5 mm²
  • Earth conductor cross section: 1.5 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 450/750 V
  • Cable flexibility: -
  • Maximum Pulling Tension: 1 kN
  • Minimum Bend Radius - During Installation (under Tension): 50 mm
  • Minimum Bend Radius - Installed: 34 mm

 

1.5mm 2C&E O/C 450/750V 500m

Nexans ref. CNHP05A5002OMAA

  • Packaging: Spool (500m)
  • Conductor cross-section: 1.5 mm²
  • Earth conductor cross section: 1.5 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 450/750 V
  • Cable flexibility: -
  • Maximum Pulling Tension: 1 kN
  • Minimum Bend Radius - During Installation (under Tension): 50 mm
  • Minimum Bend Radius - Installed: 34 mm

 

1.5mm 3C&E O/C 0.6/1KV

Nexans ref. FNHP05AA003OMAA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 1.5 mm²
  • Earth conductor cross section: 1.5 mm²
  • Number of cores: 3
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.3 kN
  • Minimum Bend Radius - During Installation (under Tension): 66 mm
  • Minimum Bend Radius - Installed: 44 mm

 

1.5mm 3C&E O/C 0.6/1KV 100m

Nexans ref. FNHP05A1003OMAA

  • Packaging: Spool (100m)
  • Conductor cross-section: 1.5 mm²
  • Earth conductor cross section: 1.5 mm²
  • Number of cores: 3
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.3 kN
  • Minimum Bend Radius - During Installation (under Tension): 66 mm
  • Minimum Bend Radius - Installed: 44 mm

 

1.5mm 3C&E O/C 0.6/1KV 500m

Nexans ref. FNHP05A5003OMAA

  • Packaging: Spool (500m)
  • Conductor cross-section: 1.5 mm²
  • Earth conductor cross section: 1.5 mm²
  • Number of cores: 3
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.3 kN
  • Minimum Bend Radius - During Installation (under Tension): 66 mm
  • Minimum Bend Radius - Installed: 44 mm

 

10mm 2C&E 0.6/1 kv O/C

Nexans ref. DNHP13AA002OMAA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 10 mm²
  • Earth conductor cross section: 4 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.9 kN
  • Minimum Bend Radius - During Installation (under Tension): 97 mm
  • Minimum Bend Radius - Installed: 64 mm

 

10mm 2C&E 0.6/1 kv O/C 100m

Nexans ref. DNHP13A1002OMAA

  • Packaging: Spool (100m)
  • Conductor cross-section: 10 mm²
  • Earth conductor cross section: 4 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.7 kN
  • Minimum Bend Radius - During Installation (under Tension): 84 mm
  • Minimum Bend Radius - Installed: 56 mm

 

10mm 2C&E 0.6/1 kv O/C 500m

Nexans ref. DNHP13A5002OMAA

  • Packaging: Spool (500m)
  • Conductor cross-section: 10 mm²
  • Earth conductor cross section: 4 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.7 kN
  • Minimum Bend Radius - During Installation (under Tension): 84 mm
  • Minimum Bend Radius - Installed: 56 mm

 

10mm 3C&E O/C 0.6/1KV

Nexans ref. FNHP13AA003OMAA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 10 mm²
  • Earth conductor cross section: 4 mm²
  • Number of cores: 3
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility: -
  • Maximum Pulling Tension: 2.1 kN
  • Minimum Bend Radius - During Installation (under Tension): 105 mm
  • Minimum Bend Radius - Installed: 70 mm

 

16mm 2C&E O/C 0.6/1KV

Nexans ref. DNHP15AA002OMAA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 16 mm²
  • Earth conductor cross section: 6 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility: -
  • Maximum Pulling Tension: 2.2 kN
  • Minimum Bend Radius - During Installation (under Tension): 110 mm
  • Minimum Bend Radius - Installed: 72 mm

 

16mm 2C&E O/C 0.6/1KV 100m

Nexans ref. DNHP15A1002OMAA

  • Packaging: Spool (100m)
  • Conductor cross-section: 16 mm²
  • Earth conductor cross section: 6 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility: -
  • Maximum Pulling Tension: 2.2 kN
  • Minimum Bend Radius - During Installation (under Tension): 110 mm
  • Minimum Bend Radius - Installed: 72 mm

 

16mm 2C&E O/C 0.6/1KV 500m

Nexans ref. DNHP15A5002OMAA

  • Packaging: Spool (500m)
  • Conductor cross-section: 16 mm²
  • Earth conductor cross section: 6 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility: -
  • Maximum Pulling Tension: 2.2 kN
  • Minimum Bend Radius - During Installation (under Tension): 110 mm
  • Minimum Bend Radius - Installed: 72 mm

 

16mm 3C&E O/C 0.6/1KV

Nexans ref. FNHP15AA003OMAA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 16 mm²
  • Earth conductor cross section: 6 mm²
  • Number of cores: 3
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility: -
  • Maximum Pulling Tension: 2.4 kN
  • Minimum Bend Radius - During Installation (under Tension): 118 mm
  • Minimum Bend Radius - Installed: 78 mm

 

2.5mm 2C&E O/C (450/750v) 100m

Nexans ref. CNHP07A1002OMAA

  • Packaging: Spool (100m)
  • Conductor cross-section: 2.5 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 450/750 V
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.2 kN
  • Minimum Bend Radius - During Installation (under Tension): 59 mm
  • Minimum Bend Radius - Installed: 39 mm

 

2.5mm 2C&E O/C (450/750v) 500m

Nexans ref. CNHP07A5002OMAA

  • Packaging: Spool (500m)
  • Conductor cross-section: 2.5 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 450/750 V
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.2 kN
  • Minimum Bend Radius - During Installation (under Tension): 59 mm
  • Minimum Bend Radius - Installed: 39 mm

 

2.5mm 2C&E O/C 0.6/1KV

Nexans ref. DNHP07AA002OMAA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 2.5 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.4 kN
  • Minimum Bend Radius - During Installation (under Tension): 68 mm
  • Minimum Bend Radius - Installed: 45 mm

 

2.5mm 2C&E O/C 0.6/1KV 100m

Nexans ref. DNHP07A1002OMAA

  • Packaging: Spool (100m)
  • Conductor cross-section: 2.5 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.4 kN
  • Minimum Bend Radius - During Installation (under Tension): 68 mm
  • Minimum Bend Radius - Installed: 45 mm

 

2.5mm 2C&E O/C 0.6/1KV 500m

Nexans ref. DNHP07A5002OMAA

  • Packaging: Spool (500m)
  • Conductor cross-section: 2.5 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility: -
  • Maximum Pulling Tension: - kN
  • Minimum Bend Radius - During Installation (under Tension): - mm
  • Minimum Bend Radius - Installed: - mm

 

2.5mm 3C&E O/C (450/750V ) 100m

Nexans ref. ENHP05A1003OMAA

  • Packaging: Spool (100m)
  • Conductor cross-section: 1.5 mm²
  • Earth conductor cross section: 1.5 mm²
  • Number of cores: 3
  • Rated Voltage Uo/U (Um): 450/750 V
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.1 kN
  • Minimum Bend Radius - During Installation (under Tension): 55 mm
  • Minimum Bend Radius - Installed: 37 mm

 

2.5mm 3C&E O/C (450/750V ) 100m

Nexans ref. ENHP07A1003OMAA

  • Packaging: Spool (100m)
  • Conductor cross-section: 2.5 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 3
  • Rated Voltage Uo/U (Um): 450/750 V
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.3 kN
  • Minimum Bend Radius - During Installation (under Tension): 67 mm
  • Minimum Bend Radius - Installed: 44 mm

 

2.5mm 3C&E O/C (450/750v) 500m

Nexans ref. ENHP07A5003OMAA

  • Packaging: Spool (500m)
  • Conductor cross-section: 2.5 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 3
  • Rated Voltage Uo/U (Um): 450/750 V
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.3 kN
  • Minimum Bend Radius - During Installation (under Tension): 67 mm
  • Minimum Bend Radius - Installed: 44 mm

 

2.5mm 3C&E O/C (450/750v) 500m

Nexans ref. ENHP05A5003OMAA

  • Packaging: Spool (500m)
  • Conductor cross-section: 1.5 mm²
  • Earth conductor cross section: 1.5 mm²
  • Number of cores: 3
  • Rated Voltage Uo/U (Um): 450/750 V
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.1 kN
  • Minimum Bend Radius - During Installation (under Tension): 55 mm
  • Minimum Bend Radius - Installed: 37 mm

 

2.5mm 3C&E O/C 0.6/1KV

Nexans ref. FNHP07AA003OMAA

  • Packaging: Spool (m)
  • Conductor cross-section: 2.5 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 3
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility: Class 2
  • Maximum Pulling Tension: 1.5 kN
  • Minimum Bend Radius - During Installation (under Tension): 74 mm
  • Minimum Bend Radius - Installed: 49 mm

 

4mm 2C&E 0.6/1 kv O/C

Nexans ref. DNHP09AA002OMAA

  • Packaging: Cut to length (500m)
  • Conductor cross-section: 4 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility:
  • Maximum Pulling Tension: 1.6 kN
  • Minimum Bend Radius - During Installation (under Tension): 79 mm
  • Minimum Bend Radius - Installed: 52 mm

 

4mm 2C&E 0.6/1 kv O/C 500m

Nexans ref. DNHP09A5002OMAA

  • Packaging: Spool (500m)
  • Conductor cross-section: 4 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility:
  • Maximum Pulling Tension: 1.6 kN
  • Minimum Bend Radius - During Installation (under Tension): 79 mm
  • Minimum Bend Radius - Installed: 52 mm

 

4mm 2C&E O/C (450/750v) 100m

Nexans ref. CNHP09A1002OMAA

  • Packaging: Spool (100m)
  • Conductor cross-section: 4 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 450/750 V
  • Cable flexibility:
  • Maximum Pulling Tension: 1.4 kN
  • Minimum Bend Radius - During Installation (under Tension): 68 mm
  • Minimum Bend Radius - Installed: 46 mm

 

4mm 2C&E O/C (450/750v) 500m

Nexans ref. CNHP09A5002OMAA

  • Packaging: Spool (500m)
  • Conductor cross-section: 4 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 450/750 V
  • Cable flexibility:
  • Maximum Pulling Tension: 1.4 kN
  • Minimum Bend Radius - During Installation (under Tension): 68 mm
  • Minimum Bend Radius - Installed: 46 mm

 

4mm 3C&E O/C (450/750V ) 100m

Nexans ref. ENHP09A1003OMAA

  • Packaging: Spool (100m)
  • Conductor cross-section: 4 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 3
  • Rated Voltage Uo/U (Um): 450/750 V
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.5 kN
  • Minimum Bend Radius - During Installation (under Tension): 75 mm
  • Minimum Bend Radius - Installed: 50 mm

 

4mm 3C&E O/C (450/750v) 500m

Nexans ref. ENHP09A5003OMAA

  • Packaging: Spool (500m)
  • Conductor cross-section: 4 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 3
  • Rated Voltage Uo/U (Um): 450/750 V
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.5 kN
  • Minimum Bend Radius - During Installation (under Tension): 75 mm
  • Minimum Bend Radius - Installed: 50 mm

 

4mm 3C&E O/C 0.6/1KV

Nexans ref. FNHP09AA003OMAA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 4 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 3
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.7 kN
  • Minimum Bend Radius - During Installation (under Tension): 85 mm
  • Minimum Bend Radius - Installed: 56 mm

 

6mm 2C&E 0.6/1 kv O/C

Nexans ref. DNHP11AA002OMAA

  • Packaging: Cut to length (500m)
  • Conductor cross-section: 6 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.7 kN
  • Minimum Bend Radius - During Installation (under Tension): 84 mm
  • Minimum Bend Radius - Installed: 56 mm

 

6mm 2C&E 0.6/1 kv O/C 100m

Nexans ref. DNHP11A1002OMAA

  • Packaging: Spool (100m)
  • Conductor cross-section: 6 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.7 kN
  • Minimum Bend Radius - During Installation (under Tension): 84 mm
  • Minimum Bend Radius - Installed: 56 mm

 

6mm 2C&E O/C 450/750V

Nexans ref. CNHP11AA002OMAA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 6 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 450/750 V
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.5 kN
  • Minimum Bend Radius - During Installation (under Tension): 74 mm
  • Minimum Bend Radius - Installed: 50 mm

 

6mm 2C&E O/C 450/750V 100m

Nexans ref. CNHP11A1002OMAA

  • Packaging: Spool (100m)
  • Conductor cross-section: 6 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 450/750 V
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.5 kN
  • Minimum Bend Radius - During Installation (under Tension): 74 mm
  • Minimum Bend Radius - Installed: 50 mm

 

6mm 2C&E O/C 450/750V 500m

Nexans ref. CNHP11A5002OMAA

  • Packaging: Spool (500m)
  • Conductor cross-section: 6 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 2
  • Rated Voltage Uo/U (Um): 450/750 V
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.5 kN
  • Minimum Bend Radius - During Installation (under Tension): 74 mm
  • Minimum Bend Radius - Installed: 50 mm

 

6mm 3C&E O/C (450/750v)

Nexans ref. ENHP11AA003OMAA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 6 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 3
  • Rated Voltage Uo/U (Um): 450/750 V
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.6 kN
  • Minimum Bend Radius - During Installation (under Tension): 81 mm
  • Minimum Bend Radius - Installed: 54 mm

 

6mm 3C&E O/C (450/750v) 500m

Nexans ref. ENHP11A5003OMAA

  • Packaging: Spool (500m)
  • Conductor cross-section: 4 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 3
  • Rated Voltage Uo/U (Um): 450/750 V
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.6 kN
  • Minimum Bend Radius - During Installation (under Tension): 81 mm
  • Minimum Bend Radius - Installed: 54 mm

 

6mm 3C&E O/C 0.6/1KV

Nexans ref. FNHP11AA003OMAA

  • Packaging: Cut to length (m)
  • Conductor cross-section: 6 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 3
  • Rated Voltage Uo/U (Um): 0,6/1 kV
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.8 kN
  • Minimum Bend Radius - During Installation (under Tension): 91 mm
  • Minimum Bend Radius - Installed: 60 mm

 

6mm 3C&E O/C 450/750V 100m

Nexans ref. ENHP11A1003OMAA

  • Packaging: Spool (100m)
  • Conductor cross-section: 4 mm²
  • Earth conductor cross section: 2.5 mm²
  • Number of cores: 3
  • Rated Voltage Uo/U (Um): 450/750 V
  • Cable flexibility: -
  • Maximum Pulling Tension: 1.6 kN
  • Minimum Bend Radius - During Installation (under Tension): 81 mm
  • Minimum Bend Radius - Installed: 54 mm

 

Description

Description

Standards

  • National
    AS/NZS 1125; AS/NZS 5000; AS/NZS 5000.1; AS/NZS 5000.2
  • 2 & 3 core+earth, circular,
  • V-90 insulated,
  • 90°C PVC sheathed to AS/NZS 5000,
  • Stranded Copper conductors

Note: Cores smaller than 25mm2 are not compacted. 
 

PVC Circular; Orange Circular ; Circs

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Colour
Orange
Conductor material
Copper
Conductor shape
Circular
Insulation
V-90
Outer sheath
PVC
Type of conductor
Stranded copper

Resources

Resources

Documentation

xls — 0 B

PVC Circular (2 Core+E) - Current carrying capacities single phase (in Amps)

Copper Conductor

Insulation PVC

Maximum Conductor Temperature 75⁰C

Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu Cu Cu
1.0 15.0 14.0 11.0 7.0 13.0 10.0 6.0 22.0 17.0
1.5 19.0 18.0 14.0 9.0 16.0 13.0 8.0 28.0 21.0
2.5 27.0 26.0 20.0 13.0 23.0 19.0 12.0 40.0 30.0
4.0 37.0 34.0 27.0 17.0 30.0 24.0 15.0 52.0 39.0
6.0 46.0 44.0 35.0 22.0 39.0 31.0 20.0 65.0 50.0
10.0 64.0 60.0 48.0 30.0 52.0 42.0 26.0 87.0 66.0
16.0 85.0 80.0 64.0 40.0 68.0 54.0 34.0 114.0 86.0
25.0 113.0 107.0 85.0 53.0 90.0 72.0 45.0 147.0 112.0
35.0 139.0 131.0 105.0 65.0 112.0 90.0 56.0 178.0 136.0
50.0 170.0 159.0 127.0 0.0 133.0 107.0 0.0 211.0 162.0
70.0 215.0 201.0 161.0 0.0 170.0 136.0 0.0 259.0 202.0
95.0 265.0 248.0 198.0 0.0 204.0 163.0 0.0 311.0 243.0
120.0 307.0 288.0 230.0 0.0 241.0 192.0 0.0 355.0 282.0
150.0 351.0 328.0 263.0 0.0 271.0 217.0 0.0 398.0 317.0
185.0 403.0 377.0 302.0 0.0 313.0 250.0 0.0 449.0 363.0
240.0 477.0 446.0 357.0 0.0 364.0 291.0 0.0 520.0 421.0
300.0 547.0 511.0 409.0 0.0 424.0 340.0 0.0 586.0 483.0
400.0 631.0 589.0 471.0 0.0 482.0 386.0 0.0 663.0 548.0
500.0 716.0 668.0 534.0 0.0 561.0 449.0 0.0 741.0 628.0
Unenclosed spaced
Unenclosed touching
Unenclosed and partially surrounded by thermal insulation
Unenclosed and completely surrounded by thermal insulation
Enclosed conduit in air
Enclosed, partially surrounded by thermal insulation
Enclosed, completely surrounded by thermal insulation
Buried direct
Underground ducts

PVC Circular 3C + 4C and Earth - Current carrying capacities three phase (in Amps)

Copper Conductor

Insulation PVC

Maximum Conductor Temperature 75⁰C

Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu Cu Cu
1.0 13.0 12.0 9.0 6.0 11.0 9.0 5.0 19.0 14.0
1.5 16.0 15.0 12.0 8.0 14.0 11.0 7.0 24.0 18.0
2.5 23.0 22.0 17.0 11.0 20.0 16.0 10.0 34.0 25.0
4.0 31.0 29.0 23.0 15.0 25.0 20.0 13.0 44.0 33.0
6.0 40.0 37.0 30.0 19.0 33.0 26.0 16.0 55.0 42.0
10.0 54.0 51.0 41.0 25.0 44.0 35.0 22.0 74.0 55.0
16.0 72.0 68.0 54.0 34.0 58.0 47.0 29.0 96.0 73.0
25.0 97.0 91.0 73.0 46.0 76.0 60.0 38.0 125.0 94.0
35.0 120.0 112.0 90.0 56.0 94.0 75.0 47.0 150.0 114.0
50.0 146.0 137.0 109.0 0.0 112.0 89.0 0.0 178.0 136.0
70.0 185.0 172.0 138.0 0.0 142.0 114.0 0.0 219.0 170.0
95.0 228.0 213.0 170.0 0.0 177.0 142.0 0.0 263.0 208.0
120.0 265.0 247.0 198.0 0.0 202.0 162.0 0.0 300.0 237.0
150.0 303.0 282.0 226.0 0.0 228.0 182.0 0.0 336.0 266.0
185.0 348.0 324.0 259.0 0.0 263.0 211.0 0.0 379.0 304.0
240.0 412.0 383.0 307.0 0.0 316.0 253.0 0.0 438.0 359.0
300.0 472.0 438.0 0.0 0.0 0.0 0.0 0.0 493.0 404.0
400.0 544.0 504.0 0.0 0.0 0.0 0.0 0.0 557.0 468.0
500.0 616.0 571.0 0.0 0.0 0.0 0.0 0.0 620.0 522.0
Unenclosed spaced
Unenclosed touching
Unenclosed and partially surrounded by thermal insulation
Unenclosed and completely surrounded by thermal insulation
Enclosed conduit in air
Enclosed, partially surrounded by thermal insulation
Enclosed, completely surrounded by thermal insulation
Buried direct
Underground ducts

Find a Distributor

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close