Fire Resistant (FR) Single Core
Fire Resistant (FR) Single Core
ALSECURE®
Nexans Fire Resistant (FR) Single Core cables are a range of Fire Rated single core products for use in mains and sub-mains applications. ALSECURE® utilizes the tried and true Glass Mica Tape technology. The tape barrier provides circuit integrity in accordance with AS/NZS 3013 WS52W. 0.6/1kV Rated Single Core Fire Rated Power Cable.
Read moreFR SDI XHF 1X10 FCu HFS RD 110 WS52W
Nexans ref. PFLX01AA001JBNA - Country ref. PFLX01AA001JBNA
- Packaging: Cut to length (m)
- Conductor cross-section: 10 mm²
- Nominal overall diameter: 9.7 mm
- Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
- Maximum Pull Tension of Conductor: 0 kN
- Maximum Pulling Tension: 0.2 kN
- Minimum Bend Radius - During Installation (under Tension): 87 mm
- Minimum Bend Radius - Installed: 58 mm
FR SDI XHF 1X120 FCu HFS RD 110 WS52W
Nexans ref. PFLE87AA001JBNA - Country ref. PFLE87AA001JBNA
- Packaging: Cut to length (m)
- Conductor cross-section: 120 mm²
- Nominal overall diameter: 21.7 mm
- Max. DC resistance of the conductor at 20°C: 0.161 Ohm/km
- Maximum Pull Tension of Conductor: 2 kN
- Maximum Pulling Tension: 2.4 kN
- Minimum Bend Radius - During Installation (under Tension): 200 mm
- Minimum Bend Radius - Installed: 130 mm
FR SDI XHF 1X150 FCu HFS RD 110 WS52W
Nexans ref. PFLE88AA001JBNA - Country ref. PFLE88AA001JBNA
- Packaging: Cut to length (m)
- Conductor cross-section: 150 mm²
- Nominal overall diameter: 23.6 mm
- Max. DC resistance of the conductor at 20°C: 0.129 Ohm/km
- Maximum Pull Tension of Conductor: 3 kN
- Maximum Pulling Tension: 3 kN
- Minimum Bend Radius - During Installation (under Tension): 210 mm
- Minimum Bend Radius - Installed: 140 mm
FR SDI XHF 1X16 FCu HFS RD 110 WS52W
Nexans ref. PFLX02AA001JBNA - Country ref. PFLX02AA001JBNA
- Packaging: Cut to length (m)
- Conductor cross-section: 16 mm²
- Nominal overall diameter: 10.9 mm
- Max. DC resistance of the conductor at 20°C: 1.21 Ohm/km
- Maximum Pull Tension of Conductor: 0 kN
- Maximum Pulling Tension: 0.32 kN
- Minimum Bend Radius - During Installation (under Tension): 98 mm
- Minimum Bend Radius - Installed: 65 mm
FR SDI XHF 1X185 FCu HFS RD 110 WS52W
Nexans ref. PFLE89AA001JBNA - Country ref. PFLE89AA001JBNA
- Packaging: Cut to length (m)
- Conductor cross-section: 185 mm²
- Nominal overall diameter: 26.3 mm
- Max. DC resistance of the conductor at 20°C: 0.106 Ohm/km
- Maximum Pull Tension of Conductor: 4 kN
- Maximum Pulling Tension: 3.7 kN
- Minimum Bend Radius - During Installation (under Tension): 320 mm
- Minimum Bend Radius - Installed: 210 mm
Description
Description
Standards
-
ProductAS/NZS 5000.1
-
InstallationAS/NZS 3013
-
TestAS/NZS 4507; IEC 60332-3 Cat.A
Construction
Stranded Flexible (Class 5) Plain Annealed Copper Conductor, Mica Taped,
X-HF-110 Insulated, HFS-110-TP Sheathed to AS/NZS 5000.1, 110°C, WS52W Fire Rated to AS/NZS 3013.
Nexans Fire Resistant (FR) Single Core cables are a range of Fire Rated single core products for use in mains and sub-mains applications.
Rated to 0.6/1kV, 110°C, this Low Fire Hazard (LSZH/LS0H) range of Fire Resistant cables will maintain circuit integrity and life-saving essential services in the event of fire. The Nexans FR Single Core range is readily available in sizes from 10mm² to 630mm².
Features
- Flexible stranded copper conductor
- Halogen free, low smoke and low corrosive/acid emissions, & flame retardant materials
- 110ºC rated insulation and sheath
- WS52W Rated to AS/NZS 3013
- Cat A bunched flame propagation to IEC 60332-3
- RHE-3 to AS/NZS 4507
- Meets physical property requirements of 125°C XLPO insulation to UL 1581
Benefits and applications
- Flexibility for fast, easy installation
- Contributes to the green star rating of your project
- Safer evacuation and better protection for essential building systems
The Nexans FR product range is suitable for Green Star Buildings as they do not contain any PVC.
Applications
- Fire resistant Power Circuit
- Consumer mains and Subs Mains
- Lift sub mains
- Power Cable to fire pumps and essential circuits
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Alsecure Plus single core - Current carrying capacity table single phase (in Amps)
Flexible Copper Conductor
Insulation X-HF-110
Maximum Conductor Temperature 110⁰C
Conductor cross-section |
|
|
|
|
|
|
|
|
|
---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
Conductor cross-section 1.0 |
|||||||||
Conductor cross-section 1.5 |
|||||||||
Conductor cross-section 2.5 |
|||||||||
Conductor cross-section 4.0 |
|||||||||
Conductor cross-section 6.0 |
|||||||||
Conductor cross-section 10.0 |
|||||||||
Conductor cross-section 16.0 |
|||||||||
Conductor cross-section 25.0 |
|||||||||
Conductor cross-section 35.0 |
|||||||||
Conductor cross-section 50.0 |
|||||||||
Conductor cross-section 70.0 |
|||||||||
Conductor cross-section 95.0 |
|||||||||
Conductor cross-section 120.0 |
|||||||||
Conductor cross-section 150.0 |
|||||||||
Conductor cross-section 185.0 |
|||||||||
Conductor cross-section 240.0 |
|||||||||
Conductor cross-section 300.0 |
|||||||||
Conductor cross-section 400.0 |
|||||||||
Conductor cross-section 500.0 |
|||||||||
Conductor cross-section 630.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Enclosed, partially surrounded by thermal insulation |
Enclosed, completely surrounded by thermal insulation |
Buried direct |
Underground Wiring Enclosure |
Individual wiring enclosure |
Alsecure Plus single core - Current carrying capacity table three phase (in Amps)
Flexible Copper Conductor
Insulation X-HF-110
Maximum Conductor Temperature 110⁰C
Conductor cross-section |
|
|
|
|
|
|
|
|
|
---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
Conductor cross-section 1.0 |
|||||||||
Conductor cross-section 1.5 |
|||||||||
Conductor cross-section 2.5 |
|||||||||
Conductor cross-section 4.0 |
|||||||||
Conductor cross-section 6.0 |
|||||||||
Conductor cross-section 10.0 |
|||||||||
Conductor cross-section 16.0 |
|||||||||
Conductor cross-section 25.0 |
|||||||||
Conductor cross-section 35.0 |
|||||||||
Conductor cross-section 50.0 |
|||||||||
Conductor cross-section 70.0 |
|||||||||
Conductor cross-section 95.0 |
|||||||||
Conductor cross-section 120.0 |
|||||||||
Conductor cross-section 150.0 |
|||||||||
Conductor cross-section 185.0 |
|||||||||
Conductor cross-section 240.0 |
|||||||||
Conductor cross-section 300.0 |
|||||||||
Conductor cross-section 400.0 |
|||||||||
Conductor cross-section 500.0 |
|||||||||
Conductor cross-section 630.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Enclosed, partially surrounded by thermal insulation |
Enclosed, completely surrounded by thermal insulation |
Buried direct |
Underground Wiring Enclosure |
Individual wiring enclosure |