1X150mm2 Versolex Orange

Description

Description

Standards

  • National
    AS/NZS 5000.1
  • 0.6/1kV cables,
  • Flexible X-90 (XLPE) insulated
  • TPE sheathed to AS/NZS5000.1 (Power),
  • Copper conductors, 90°C.
  • Submersible up to 500m

 

Also available in Low Smoke Zero Halogen materials at 110°C. See Alsecure Envirolex under "Fire Performance".

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Colour
Orange
Conductor flexibility
Class 5
Conductor material
Copper
Conductor shape
Circular
Insulation
X-90
Outer sheath
TPE
Type of conductor
Copper
With Green/Yellow core
No
With smaller neutral conductor
No

Dimensional characteristics

Dimensional characteristics

Approximate weight
151.0 kg/100m
Cable length
- m
Conductor cross-section
150 mm²
Maximum diameter of wires
0.51 mm
Neutral conductor section (when smaller)
- mm²
Nominal overall diameter
22.5 mm
Number of cores
1

Electrical characteristics

Electrical characteristics

Conductor AC resistance at 50 Hz
0.166 Ohm/km
Inductive reactance at 50Hz - flat touching
0.101 Ohm/km
Inductive reactance at 50Hz - trefoil
0.085 Ohm/km
Insulation resistance at 20°C
200 MOhm.km
Max. DC resistance of the conductor at 20°C
0.129 Ohm/km
Rated Voltage Uo/U (Um)
0,6/1 kV

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Flexible

Usage characteristics

Usage characteristics

Bending factor when installed
D>25mm: 6 (xD); D<25mm: 4 (xD)
Maximum operating temperature
90 °C

Resources

Resources

Versolex Single Core - Current carrying capacity table single phase (in Amps)

Insulation type: X-90, X-HF-90, R-EP-90, R-CPE-90, R-HF-90 OR R-CSP-90 Maximum conductor temperature: 90°C Reference ambient temperature: 40°C IN AIR, 25°C IN GROUND
Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu Cu Cu
150.0 483.0 448.0 373.0 336.0 269.0 0.0 473.0 368.0 395.0
Unenclosed spaced
Unenclosed spaced from surface
Unenclosed touching
Enclosed conduit in air
Thermal insulation, partially surrounded by thermal insulation
Thermal Insulation, completely surrounded by thermal insulation
Buried direct
Underground Wiring Enclosure
Individual Wiring Enclosure

Versolex Single Core - Current carrying capacity table three phase (in Amps)

Insulation type: X-90, X-HF-90, R-EP-90, R-CPE-90, R-HF-90 OR R-CSP-90 Maximum conductor temperature: 90°C Reference ambient temperature: 40°C IN AIR, 25°C IN GROUND
Conductor cross-section
mm² Cu Cu Cu Cu Cu Cu Cu Cu Cu
150.0 470.0 400.0 372.0 291.0 233.0 0.0 394.0 316.0 352.0
Unenclosed spaced
Unenclosed spaced from surface
Unenclosed touching
Enclosed conduit in air
Thermal insulation, partially surrounded by thermal insulation
Thermal Insulation, completely surrounded by thermal insulation
Buried direct
Underground Wiring Enclosure
Individual Wiring Enclosure

Dealer locator

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close