ENVIROLEX® Flexible Multicore 110°C
ENVIROLEX® Flexible Multicore 110°C
ENVIROLEX
Multicore flexible copper conductor, 0.6/1kV X-HF-110 insulated, HFS-110-TP sheathed to AS/NZS 5000.1, Low fire hazard insulation and sheath, 110°C continuous
Read more2C+E 1.5mm2 Cu Flexible Envirolex
Nexans ref. PTHR04AA002CXHF - Country ref. PTHR04AA002CXHF
- Packaging: Cut to length (m)
- Approximate weight: 13.0 kg/100m
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.5 mm
- Earth conductor cross section: 1.5 mm²
- Nominal overall diameter: 9.9 mm
- Number of cores: 2
2C+E 2.5mm2 Cu Flexible Envirolex
Nexans ref. PTHR05AA002CXHF - Country ref. PTHR05AA002CXHF
- Packaging: Cut to length (m)
- Approximate weight: 16.6 kg/100m
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 1.9 mm
- Earth conductor cross section: 2.5 mm²
- Nominal overall diameter: 10.8 mm
- Number of cores: 2
2C+E 4mm2 Cu Flexible Envirolex
Nexans ref. PTHR06AA002CXHF - Country ref. PTHR06AA002CXHF
- Packaging: Cut to length (m)
- Approximate weight: 19.9 kg/100m
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.6 mm
- Earth conductor cross section: 2.5 mm²
- Nominal overall diameter: 11.9 mm
- Number of cores: 2
2C+E 6mm2 Cu Flexible Envirolex
Nexans ref. PTHR07AA002CXHF - Country ref. PTHR07AA002CXHF
- Packaging: Cut to length (m)
- Approximate weight: 22.0 kg/100m
- Conductor cross-section: 6 mm²
- Conductor diameter: 3.2 mm
- Earth conductor cross section: 2.5 mm²
- Nominal overall diameter: 13.4 mm
- Number of cores: 2
3C+E 2.5mm2 Cu Flexible Envirolex
Nexans ref. PTHR05AA003CXRJ - Country ref. PTHR05AA003CXRJ
- Packaging: Cut to length (m)
- Approximate weight: 20.0 kg/100m
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 1.9 mm
- Earth conductor cross section: 2.5 mm²
- Nominal overall diameter: 12.0 mm
- Number of cores: 3
3C+E 4mm2 Cu Flexible Envirolex
Nexans ref. PTHR06AA003CXRJ - Country ref. PTHR06AA003CXRJ
- Packaging: Cut to length (m)
- Approximate weight: 24.7 kg/100m
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.6 mm
- Earth conductor cross section: 2.5 mm²
- Nominal overall diameter: 13.1 mm
- Number of cores: 3
3C+E 95mm2 Cu Flexible Envirolex
Nexans ref. PTHX64AA003CXRJ
- Packaging: m
- Approximate weight: 329.1 kg/100m
- Conductor cross-section: 95 mm²
- Conductor diameter: 12.8 mm
- Earth conductor cross section: 25 mm²
- Nominal overall diameter: 37.3 mm
- Number of cores: 3
4C+E 1.5mm2 Cu Flexible Envirolex
Nexans ref. PTHR04AA004CXEM - Country ref. PTHR04AA004CXEM
- Packaging: Cut to length (m)
- Approximate weight: 18.5 kg/100m
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.5 mm
- Earth conductor cross section: 1.5 mm²
- Nominal overall diameter: 11.6 mm
- Number of cores: 4
4C+E 10mm2 Cu Flexible Envirolex
Nexans ref. PTHR08AA004CXEM
- Packaging: m
- Approximate weight: 57.4 kg/100m
- Conductor cross-section: 10 mm²
- Conductor diameter: 4.1 mm
- Earth conductor cross section: 4 mm²
- Nominal overall diameter: 18.1 mm
- Number of cores: 4
4C+E 16mm2 Cu Flexible Envirolex
Nexans ref. PTHR09AA004CXEM
- Packaging: m
- Approximate weight: 83.5 kg/100m
- Conductor cross-section: 16 mm²
- Conductor diameter: 5.7 mm
- Earth conductor cross section: 6 mm²
- Nominal overall diameter: 22.0 mm
- Number of cores: 4
4C+E 2.5mm2 Cu Flexible Envirolex
Nexans ref. PTHR05AA004CXEM - Country ref. PTHR05AA004CXEM
- Packaging: Cut to length (m)
- Approximate weight: 24.1 kg/100m
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 1.9 mm
- Earth conductor cross section: 2.5 mm²
- Nominal overall diameter: 12.9 mm
- Number of cores: 4
4C+E 25mm2 Cu Flexible Envirolex
Nexans ref. PTHX60AA004CXEM
- Packaging: m
- Approximate weight: 121.0 kg/100m
- Conductor cross-section: 25 mm²
- Conductor diameter: 7.1 mm
- Earth conductor cross section: 6 mm²
- Nominal overall diameter: 25.9 mm
- Number of cores: 4
4C+E 35mm2 Cu Flexible Envirolex
Nexans ref. PTHX61AA004CXEM
- Packaging: m
- Approximate weight: 163.0 kg/100m
- Conductor cross-section: 35 mm²
- Conductor diameter: 8.4 mm
- Earth conductor cross section: 10 mm²
- Nominal overall diameter: 29.2 mm
- Number of cores: 4
4C+E 4mm2 Cu Flexible Envirolex
Nexans ref. PTHR06AA004CXEM - Country ref. PTHR06AA004CXEM
- Packaging: Cut to length (m)
- Approximate weight: 30.6 kg/100m
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.6 mm
- Earth conductor cross section: 2.5 mm²
- Nominal overall diameter: 14.2 mm
- Number of cores: 4
4C+E 50mm2 Cu Flexible Envirolex
Nexans ref. PTHX62AA004CXEM
- Packaging: m
- Approximate weight: 237.0 kg/100m
- Conductor cross-section: 50 mm²
- Conductor diameter: 10.1 mm
- Earth conductor cross section: 16 mm²
- Nominal overall diameter: 34.3 mm
- Number of cores: 4
4C+E 6mm2 Cu Flexible Envirolex
Nexans ref. PTHR07AA004CXEM - Country ref. PTHR07AA004CXEM
- Packaging: Cut to length (m)
- Approximate weight: 38.2 kg/100m
- Conductor cross-section: 6 mm²
- Conductor diameter: 3.2 mm
- Earth conductor cross section: 2.5 mm²
- Nominal overall diameter: 15.8 mm
- Number of cores: 4
4C+E 70mm2 Cu Flexible Envirolex
Nexans ref. PTHX63AA004CXEM
- Packaging: m
- Approximate weight: 333.1 kg/100m
- Conductor cross-section: 70 mm²
- Conductor diameter: 11.1 mm
- Earth conductor cross section: 25 mm²
- Nominal overall diameter: 37.9 mm
- Number of cores: 4
Description
Description
Standards
-
ProductAS/NZS 5000.1
-
TestAS/NZS 4507; IEC 60332-3-22 Cat.A
ENVIROLEX® flexible multicore cable is part of the Nexans Fire Safety Offer. As a Low Fire Hazard (LFH) range, ENVIROLEX® is PVC-free, made with flame retardant compound and reduces toxic smoke emissions in the event of fire, allowing time for safe evacuation.
Design
- Class 5 & 6 flexible conductor
- 0.6/1kV cables,
- Flexible, X-HF-110 insulated
- HFS-110-TP sheathed to AS/NZS 5000.1 (Power), copper conductors),
- 110°C continuous, Low smoke - zero halogen.
- Low Fire Hazard cable
- PVC-free
- Meets physical property requirements of 125°C XLPO insulation to UL 1581
110; Flexible; LS0H; LFH; Envirolex; Mains; Sub Mains; Flame Retardant
Reduced fire hazard - ideal for public buidlings and infrastructure projects where reduce flame propagation is a priority.
RHE-3 to AS/NZS 4507
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Fire safety characteristics
Fire safety characteristics
Resources
Resources
ENVIROLEX® Flexible Multicore 110°C - Current carrying capacities single phase (in Amps)
Flexible copper conductor
Maximum conductor temperature: 110°C
Reference ambient temperature: 40°C IN AIR, 25°C IN GROUND
| Conductor cross-section |
|
|
|
|
|
|
|
|---|---|---|---|---|---|---|---|
| mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
| 1.0 | 24.0 | 23.0 | 20.0 | 16.0 | 11.0 | 30.0 | 23.0 |
| 1.5 | 30.0 | 28.0 | 24.0 | 19.0 | 14.0 | 37.0 | 29.0 |
| 2.5 | 40.0 | 38.0 | 32.0 | 26.0 | 19.0 | 49.0 | 37.0 |
| 4.0 | 53.0 | 50.0 | 43.0 | 35.0 | 25.0 | 65.0 | 49.0 |
| 6.0 | 67.0 | 63.0 | 54.0 | 43.0 | 31.0 | 81.0 | 62.0 |
| 10.0 | 94.0 | 88.0 | 75.0 | 60.0 | 44.0 | 110.0 | 84.0 |
| 16.0 | 124.0 | 116.0 | 100.0 | 80.0 | 58.0 | 142.0 | 109.0 |
| 25.0 | 163.0 | 154.0 | 129.0 | 104.0 | 77.0 | 182.0 | 139.0 |
| 35.0 | 202.0 | 190.0 | 163.0 | 130.0 | 95.0 | 221.0 | 171.0 |
| 50.0 | 254.0 | 238.0 | 202.0 | 161.0 | 0.0 | 270.0 | 209.0 |
| 70.0 | 318.0 | 299.0 | 257.0 | 205.0 | 0.0 | 329.0 | 259.0 |
| 95.0 | 381.0 | 357.0 | 303.0 | 243.0 | 0.0 | 384.0 | 304.0 |
| 120.0 | 450.0 | 421.0 | 362.0 | 290.0 | 0.0 | 443.0 | 357.0 |
| 150.0 | 515.0 | 482.0 | 412.0 | 330.0 | 0.0 | 500.0 | 403.0 |
| 185.0 | 586.0 | 547.0 | 474.0 | 379.0 | 0.0 | 558.0 | 456.0 |
| 240.0 | 698.0 | 652.0 | 577.0 | 462.0 | 0.0 | 650.0 | 541.0 |
| 300.0 | 799.0 | 745.0 | 656.0 | 525.0 | 0.0 | 733.0 | 611.0 |
| 400.0 | 949.0 | 884.0 | 801.0 | 641.0 | 0.0 | 850.0 | 727.0 |
| 500.0 | 1091.0 | 1014.0 | 913.0 | 730.0 | 0.0 | 959.0 | 820.0 |
| Unenclosed spaced |
| Unenclosed touching |
| Enclosed conduit in air |
| Enclosed, partially surrounded by thermal insulation |
| Enclosed, completely surrounded by thermal insulation |
| Buried direct |
| Undergound Wiring Enclosure |
ENVIROLEX® Flexible Multicore 110°C - Current carrying capacities three phase (in Amps)
Flexible copper conductor
Maximum conductor temperature: 110°C
Reference ambient temperature: 40°C IN AIR, 25°C IN GROUND
| Conductor cross-section |
|
|
|
|
|
|
|
|---|---|---|---|---|---|---|---|
| mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
| 1.0 | 21.0 | 19.0 | 17.0 | 13.0 | 10.0 | 26.0 | 20.0 |
| 1.5 | 26.0 | 24.0 | 21.0 | 16.0 | 12.0 | 32.0 | 24.0 |
| 2.5 | 34.0 | 32.0 | 27.0 | 22.0 | 16.0 | 42.0 | 31.0 |
| 4.0 | 45.0 | 42.0 | 36.0 | 29.0 | 21.0 | 55.0 | 41.0 |
| 6.0 | 57.0 | 54.0 | 46.0 | 37.0 | 27.0 | 68.0 | 51.0 |
| 10.0 | 80.0 | 75.0 | 65.0 | 52.0 | 38.0 | 93.0 | 71.0 |
| 16.0 | 106.0 | 99.0 | 84.0 | 67.0 | 50.0 | 120.0 | 91.0 |
| 25.0 | 140.0 | 131.0 | 112.0 | 90.0 | 66.0 | 153.0 | 118.0 |
| 35.0 | 173.0 | 162.0 | 137.0 | 110.0 | 81.0 | 186.0 | 143.0 |
| 50.0 | 218.0 | 204.0 | 175.0 | 140.0 | 0.0 | 227.0 | 178.0 |
| 70.0 | 273.0 | 255.0 | 217.0 | 173.0 | 0.0 | 277.0 | 217.0 |
| 95.0 | 327.0 | 306.0 | 263.0 | 210.0 | 0.0 | 323.0 | 259.0 |
| 120.0 | 387.0 | 360.0 | 306.0 | 245.0 | 0.0 | 373.0 | 298.0 |
| 150.0 | 444.0 | 413.0 | 356.0 | 285.0 | 0.0 | 420.0 | 341.0 |
| 185.0 | 505.0 | 470.0 | 402.0 | 321.0 | 0.0 | 469.0 | 381.0 |
| 240.0 | 602.0 | 559.0 | 489.0 | 391.0 | 0.0 | 546.0 | 453.0 |
| 300.0 | 688.0 | 638.0 | 0.0 | 0.0 | 0.0 | 614.0 | 509.0 |
| 400.0 | 817.0 | 756.0 | 0.0 | 0.0 | 0.0 | 711.0 | 606.0 |
| 500.0 | 936.0 | 865.0 | 0.0 | 0.0 | 0.0 | 799.0 | 680.0 |
| Unenclosed spaced |
| Unenclosed touching |
| Enclosed conduit in air |
| Enclosed, partially surrounded by thermal insulation |
| Enclosed, completely surrounded by thermal insulation |
| Buried direct |
| Undergound Wiring Enclosure |
Selling & delivery Information
Nexans Fire Safety Offer ENVIROLEX® Low Fire Hazard Cables PVC-free Red List Free and Declare Labelled Green Star Flexible conductor
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania