2.5mm2 PVC SDI Red Insulation White Sheath 100m
2.5mm2 PVC SDI Red Insulation White Sheath 100m
2.5mm2 PVC SDI Red Insulation White Sheath 100m
Read more- Nexans ref. : AABP07A1001WTRD
- EAN : 9322576239952
Description
Description
Standards
-
NationalAS/NZS 1125; AS/NZS 5000.1; AS/NZS 5000.2
Single Core PVC SDI Cable
- Single core, V-90 insulated,
- PVC sheathed to AS/NZS 5000,
- Copper conductors, 90°C.
- 1.0 to 16mm2 450/750V to AS/NZS 5000.2
- Larger sizes; 25 to 630mm2 0.6/1kV to AS/NZS 5000.1 are available on request
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Colour
White / red
Conductor flexibility
Class 2
Conductor material
Copper
Conductor shape
Circular
Insulation
V-90
Outer sheath
PVC
Type of conductor
Stranded copper
Dimensional characteristics
Dimensional characteristics
Approximate weight
4.8 kg/100m
Cable length
100 m
Conductor cross-section
2.5 mm²
Nominal insulation thickness
0.7 mm
Nominal outer sheath thickness
0.8 mm
Nominal overall diameter
5.1 mm
Number of cores
1
Electrical characteristics
Electrical characteristics
Conductor AC resistance at 50 Hz
9.01 Ohm/km
Inductive reactance at 50Hz - flat touching
0.159 Ohm/km
Inductive reactance at 50Hz - trefoil
0.143 Ohm/km
Insulation resistance at 20°C
9.2 MOhm.km
Max. DC resistance of the conductor at 20°C
7.41 Ohm/km
Rated Voltage Uo/U (Um)
450/750 V
Mechanical characteristics
Mechanical characteristics
Cable flexibility
Rigid
Maximum installation tension
175 N
Usage characteristics
Usage characteristics
Minimum Bend Radius - During Installation (under Tension)
31 mm
Minimum Bend Radius - Installed
20 mm
Resources
Resources
PVC SDI - Current carrying capacity table single phase (in Amps)
Copper Conductor Insulation PVC Maximum Conductor Temperature 75⁰CConductor cross-section | |||||||||
---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
2.5 | 30 | 29 | 23 | 24 | 20 | 12 | 43 | 32 | 36 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Buried direct |
Underground ducts A - Undergound Wiring Enclosure |
Underground ducts B - Individual Wiring Enclosure |
PVC SDI - Current carrying capacity table three phase (in Amps)
Copper Conductor Insulation PVC Maximum Conductor Temperature 75⁰CConductor cross-section | |||||||||
---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu | Cu |
2.5 | 29 | 25 | 23 | 21 | 17 | 12 | 37 | 27 | 33 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Buried direct |
Underground ducts A - Undergound Wiring Enclosure |
Underground ducts B - Individual Wiring Enclosure |
Dealer locator
Waiting…
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania