Type 245.3

Description

Description

Standards

  • National
    AS/NZS 1802

Semiconductive screened and flexible for use as longwall shearer cable. The flexible conductor allows for much reduced bending radii so this cable will tolerate bending in the cable chain (often called 'Bretby'). Cable has 3 central pilots for earth continuity monitoring and for control circuits.

Construction

  • Heavy duty PCP sheath
  • Open weave braid reinforcement
  • Semiconductive PCP filling and covering
  • EPR insulated and semiconductive elastomer screened power conductors
  • Semiconductive PCP covered interstitial earth conductors
  • SEmiconductive PCP cradle separator
  • EPR insulated pilot/control conductors

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Inner covering
Semiconductive PCP
Insulation
EPR
Outer sheath
Heavy duty PCP
Screen
Semiconductive Elastomer

Dimensional characteristics

Dimensional characteristics

Approximate weight
740.0 kg/100m
Conductor cross-section
95 mm²
Conductor diameter
13.9 mm
Diameter over insulation
20.7 mm
Earth Conductor - Thickness of SC PCP covering
1 mm
Earth conductor cross section
18.7 mm²
Ground Check Conductor cross-section (AWG)
-
Nominal Screen Area on each core
- mm²
Nominal insulation thickness
3.0 mm
Nominal outer sheath thickness
- mm
Nominal overall diameter
66.6 mm
Pilot Conductor Strand Size (no./mm)
28/0.25
Pilot Conductor thickness of EPR covering
0.8 mm
Sheath thickness including SC PCP layer
6 mm
Stranding (No./mm)
1332/0.30

Electrical characteristics

Electrical characteristics

A.C. Conductor resist. 50Hz and at 90 °C
0.274 Ohm/km
Charging current per phase
0.484 A/km
Conductor to screen capacitance
0.47 mF/km
DC Resistance of the Screen at 20°C
0.428 Ohm/km
Dielectric loss per phase
63.9 W/km
Inductive reactance at 50Hz
0.094 Ohm/km
Insulation resistance at 20°C
600 MOhm.km
Max. DC resistance of the conductor at 20°C
0.214 Ohm/km
Maximum electric stress
1.28 kV/mm
Rated Voltage Uo/U
3.3/3.3 kV
Voltage drop, 3 conductors
0.5 V/A.km
Zero sequence reactance at 50HZ
0.075 Ohm/km
Zero sequence resistance at 20°C
1.64 Ohm/km

Mechanical characteristics

Mechanical characteristics

Maximum Pulling Tension
5.7 kN

Usage characteristics

Usage characteristics

Minimum Bend Radius - Installed
400 mm
Minimum bending radius under free flexing
670 mm
Minimum bending radius under repeated reeling mm
800 mm

Resources

Resources

Dealer locator

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close