VAROLEX® VSD/EMC 3C+3E

Products

3X25mm2 + 3E Varolex Black

Nexans ref. FTDC17AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 12 mm²
  • Conductor cross-section: 25 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 1.82 kN
  • Minimum Bend Radius - During Installation (under Tension): 410 mm
  • Minimum Bend Radius - Installed: 270 mm

 

3x35mm2 + 3E Varolex Black

Nexans ref. FTDC18AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 18 mm²
  • Conductor cross-section: 35 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 2.29 kN
  • Minimum Bend Radius - During Installation (under Tension): 460 mm
  • Minimum Bend Radius - Installed: 310 mm

 

3x50mm2 + 3E Varolex Black

Nexans ref. FTDC19AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 30 mm²
  • Conductor cross-section: 50 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 2.9 kN
  • Minimum Bend Radius - During Installation (under Tension): 520 mm
  • Minimum Bend Radius - Installed: 350 mm

 

3x70mm2 + 3E Varolex Black

Nexans ref. FTDC20AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 30 mm²
  • Conductor cross-section: 70 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 3.58 kN
  • Minimum Bend Radius - During Installation (under Tension): 580 mm
  • Minimum Bend Radius - Installed: 380 mm

 

3x95mm2 + 3E Varolex Black

Nexans ref. FTDC22AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 48 mm²
  • Conductor cross-section: 95 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 5.05 kN
  • Minimum Bend Radius - During Installation (under Tension): 680 mm
  • Minimum Bend Radius - Installed: 460 mm

 

3X2.5mm2 + E Varolex Black

Nexans ref. FTDP07AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 2.5 mm²
  • Conductor cross-section: 2.5 mm²
  • Number of earth cores: 1
  • Maximum Pulling Tension: 0.75 kN
  • Minimum Bend Radius - During Installation (under Tension): 260 mm
  • Minimum Bend Radius - Installed: 180 mm

 

3X4mm2 + E Varolex Black

Nexans ref. FTDP09AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 4.5 mm²
  • Conductor cross-section: 4 mm²
  • Number of earth cores: 1
  • Maximum Pulling Tension: 0.96 kN
  • Minimum Bend Radius - During Installation (under Tension): 300 mm
  • Minimum Bend Radius - Installed: 200 mm

 

3X6mm2 + 3E Varolex Black

Nexans ref. FTDP11AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 4.5 mm²
  • Conductor cross-section: 6 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 1.07 kN
  • Minimum Bend Radius - During Installation (under Tension): 320 mm
  • Minimum Bend Radius - Installed: 210 mm

 

3X10mm2 + 3E Varolex Black

Nexans ref. FTDP13AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 4.5 mm²
  • Conductor cross-section: 10 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 1.2 kN
  • Minimum Bend Radius - During Installation (under Tension): 330 mm
  • Minimum Bend Radius - Installed: 220 mm

 

3X16mm2 + 3E Varolex Black

Nexans ref. FTDP15AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 7.5 mm²
  • Conductor cross-section: 16 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 1.49 kN
  • Minimum Bend Radius - During Installation (under Tension): 370 mm
  • Minimum Bend Radius - Installed: 250 mm

 

3X120mm2 + 3E Varolex Black

Nexans ref. FTDP23AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 48 mm²
  • Conductor cross-section: 120 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 6.53 kN
  • Minimum Bend Radius - During Installation (under Tension): 780 mm
  • Minimum Bend Radius - Installed: 520 mm

 

3X150mm2 + 3E Varolex Black

Nexans ref. FTDP24AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 75 mm²
  • Conductor cross-section: 150 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 7.83 kN
  • Minimum Bend Radius - During Installation (under Tension): 850 mm
  • Minimum Bend Radius - Installed: 570 mm

 

3X185mm2 + 3E Varolex Black

Nexans ref. FTDP25AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 75 mm²
  • Conductor cross-section: 185 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 9.46 kN
  • Minimum Bend Radius - During Installation (under Tension): 940 mm
  • Minimum Bend Radius - Installed: 620 mm

 

3X240mm2 + 3E Varolex Black

Nexans ref. FTDP26AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 75 mm²
  • Conductor cross-section: 240 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 12.14 kN
  • Minimum Bend Radius - During Installation (under Tension): 1060 mm
  • Minimum Bend Radius - Installed: 710 mm

 

3X300mm2 + 3E Varolex Black

Nexans ref. FTDP27AA003CXRJ

  • Packaging: Cut to length (m)
  • Combined earth size section: 150 mm²
  • Conductor cross-section: 300 mm²
  • Number of earth cores: 3
  • Maximum Pulling Tension: 14.88 kN
  • Minimum Bend Radius - During Installation (under Tension): 1170 mm
  • Minimum Bend Radius - Installed: 780 mm

 

Description

Description

Standards

  • National
    AS/NZS 1125; AS/NZS 5000.1
  • Intended for fixed variable speed drive applications
  • 0.6/1kV X-90 insulated,
  • 3 core+3 earths,
  • PVC bedded,
  • Copper tape screened,
  • PVC sheathed to AS/NZS 5000.1,
  • Stranded Copper conductors, 90°C

*For 2.5 mm², split earth not feasible, therefore a single earth conductor is utilised.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Class 2
Conductor material
Copper
Conductor shape
Circular
Insulation
X-90
Material of bedding
PVC filler
Outer sheath
PVC
Screen
Copper tape

Dimensional characteristics

Dimensional characteristics

Number of cores
3

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Maximum operating temperature
90 °C

Resources

Resources

Current carrying capacities three phase (in Amps)

Insulation type: X-90, X-HF-90, R-EP-90, R-CPE-90, R-HF-90 OR R-CSP-90

Maximum conductor temperature: 90°C

Reference ambient temperature: 40°C IN AIR, 25°C IN GROUND

Conductor cross-section
mm² Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al
1.0 16 0 14 0 12 0 7 0 13 0 10 0 6 0 22 0 16 0
1.5 20 0 19 0 15 0 9 0 16 0 13 0 8 0 28 0 20 0
2.5 28 0 26 0 21 0 13 0 24 0 19 0 12 0 39 0 29 0
4.0 38 0 35 0 28 0 18 0 30 0 24 0 15 0 51 0 37 0
6.0 48 0 45 0 36 0 22 0 38 0 30 0 19 0 63 0 46 0
10.0 66 0 62 0 49 0 31 0 53 0 42 0 26 0 85 0 63 0
16.0 88 68 83 64 66 51 41 32 68 53 55 42 34 26 110 85 81 63
25.0 119 93 111 84 89 69 56 43 91 71 73 57 46 36 143 111 107 83
35.0 147 114 137 106 110 85 69 53 114 88 91 71 57 44 172 133 130 101
50.0 180 140 168 10 134 104 0 0 136 105 108 84 0 0 204 159 155 120
70.0 229 178 213 165 170 132 0 0 173 134 138 107 0 0 251 195 193 150
95.0 283 220 263 204 210 163 0 0 209 162 167 129 0 0 302 234 233 181
120.0 330 256 306 238 245 190 0 0 246 192 197 153 0 0 344 268 270 210
150.0 377 293 350 272 280 217 0 0 277 216 222 172 0 0 385 299 304 236
185.0 436 340 404 315 323 252 0 0 322 251 257 201 0 0 435 340 348 272
240.0 517 405 479 375 383 300 0 0 386 303 309 242 0 0 504 395 411 322
300.0 594 467 549 432 0 0 0 0 0 0 0 0 0 0 567 446 463 365
400.0 685 545 632 504 0 0 0 0 0 0 0 0 0 0 640 510 524 417
500.0 779 629 718 579 0 0 0 0 0 0 0 0 0 0 714 577 601 485
Unenclosed spaced
Unenclosed touching
Unenclosed and partially surrounded by thermal insulation
Unenclosed and completely surrounded by thermal insulation
Enclosed conduit in air
Enclosed, partially surrounded by thermal insulation
Enclosed, completely surrounded by thermal insulation
Buried direct
Underground ducts A

Find a Distributor

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close