XLP 1X120 PC 0.6/1KV PVC 1000m
XLP 1X120 PC 0.6/1KV PVC 1000m
120mm2 XLPE / PVC SDI Black 1000m
Read more- Nexans ref. : BDBP23A9001CXNA
- EAN : 9319215478452
Description
Description
Standards
-
NationalAS/NZS 1125; AS/NZS 5000.1
Single core XLPE SDI Cable
- Single core, 0.6/1kV X-90 insulated,
- PVC sheathed to AS/NZS 5000.1,
- Copper conductor, 90°C.
Mains; Submains
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Colour
Black
Conductor material
Copper
Type of conductor
Compressed copper
Conductor shape
Circular
Conductor flexibility
Class 2
Insulation
X-90
Outer sheath
PVC
Dimensional characteristics
Dimensional characteristics
Approximate weight
123.0 kg/100m
Cable length
1000 m
Conductor cross-section
120 mm²
Nominal insulation thickness
1.2 mm
Nominal outer sheath thickness
1.5 mm
Nominal overall diameter
19.6 mm
Number of cores
1
Electrical characteristics
Electrical characteristics
Conductor AC resistance at 50 Hz
0.188 Ohm/km
Inductive reactance at 50Hz - flat touching
0.1 Ohm/km
Inductive reactance at 50Hz - trefoil
0.084 Ohm/km
Insulation resistance at 20°C
210 MOhm.km
Max. DC resistance of the conductor at 20°C
0.153 Ohm/km
Rated Voltage Uo/U (Um)
0,6/1 kV
Mechanical characteristics
Mechanical characteristics
Cable flexibility
Rigid
Maximum Pull Tension of Conductor
8 kN
Maximum Pulling Tension
2.4 kN
Usage characteristics
Usage characteristics
Minimum Bend Radius - During Installation (under Tension)
120 mm
Minimum Bend Radius - Installed
78 mm
Resources
Resources
XLPE/PVC single core - Current carrying capacity table single phase (in Amps)
Copper or Aluminium Conductor XLPE Insulation Maximum Conductor Temperature 90⁰CConductor cross-section | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
120.0 | 422.0 | 328.0 | 393.0 | 305.0 | 325.0 | 253.0 | 292.0 | 226.0 | 233.0 | 181.0 | 0.0 | 0.0 | 427.0 | 332.0 | 325.0 | 252.0 | 358.0 | 278.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Buried direct |
Underground ducts A - Underground Wiring Enclosure |
Underground ducts B - Individual Wiring Enclosure |
XLPE/PVC single core - Current carrying capacity table three phase (in Amps)
Copper or Aluminium Conductor XLPE Insulation Maximum Conductor Temperature 90⁰CConductor cross-section | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
mm² | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al | Cu | Al |
120.0 | 410.0 | 318.0 | 349.0 | 271.0 | 325.0 | 253.0 | 261.0 | 203.0 | 209.0 | 162.0 | 0.0 | 0.0 | 356.0 | 277.0 | 284.0 | 221.0 | 320.0 | 248.0 |
Unenclosed spaced |
Unenclosed spaced from surface |
Unenclosed touching |
Enclosed conduit in air |
Thermal insulation, partially surrounded by thermal insulation |
Thermal Insulation, completely surrounded by thermal insulation |
Buried direct |
Underground ducts A - Underground Wiring Enclosure |
Underground ducts B - Individual Wiring Enclosure |